(subscribe to this query)
NA
CVE-2022-37122
Carel pCOWeb HVAC BACnet Gateway 2.1.0, Firmware: A2.1.0 - B2.1.0, Application Software: 2.15.4A Software v16 13020200 suffers from an unauthenticated arbitrary file disclosure vulnerability. Input passed through the 'file' GET parameter through the 'logdownload.cg...
Carel Pcoweb Card Firmware
Carel Applica 2.154a
Carel Pcoweb Hvac Bacnet Gateway 2.1.0
Carel Applica 16 13020200
NA
CVE-2020-18329
An issue exists in Rehau devices that use a pCOWeb card BIOS v6.27, BOOT v5.00, web version v2.2, allows malicious users to gain full unauthenticated access to the configuration and service interface.
Carel Pcoweb Card Web 2.2
Carel Pcoweb Card Boot 5.00
Carel Pcoweb Card Bios 6.27
890
VMScore
CVE-2019-13553
Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems is configured using hard-coded credentials. These credentials could allow malicious users to influence the primary operations of...
Carel Pcoweb Firmware
445
VMScore
CVE-2019-9484
The Glen Dimplex Deutschland GmbH implementation of the Carel pCOWeb configuration tool allows remote malicious users to obtain access via an HTTP session on port 10000, as demonstrated by reading the modem password (which is 1234), or reconfiguring "party mode" or &quo...
Carel Pcoweb Card Firmware -
356
VMScore
CVE-2019-11369
An issue exists in Carel pCOWeb prior to B1.2.4. In /config/pw_changeusers.html the device stores cleartext passwords, which may allow sensitive information to be read by someone with access to the device.
Carel Pcoweb Card Firmware
312
VMScore
CVE-2019-11370
Stored XSS exists in Carel pCOWeb prior to B1.2.4, as demonstrated by the config/pw_snmp.html "System contact" field.
Carel Pcoweb Card Firmware
510
VMScore
CVE-2011-3487
Directory traversal vulnerability in CarelDataServer.exe in Carel PlantVisor 2.4.4 and previous versions allows remote malicious users to read arbitrary files via a .. (dot dot) in an HTTP GET request.
Carel Plantvisor
2 EDB exploits
445
VMScore
CVE-2019-13549
Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems does not provide a sufficient level of protection against unauthorized configuration changes. Primary operations, namely turning...
Carel Pcoweb Firmware
694
VMScore
CVE-2016-0867
CAREL PlantVisorEnhanced allows remote malicious users to bypass intended access restrictions via a direct file request.
Carel Plantvisor Enhanced
NA
CVE-2022-34827
Carel Boss Mini 1.5.0 has Improper Access Control.
Carel Boss Mini Firmware 1.5.0
VMScore
CVSSv2
CVSSv3
VMScore
Recommendations:
hardcoded
arbitrary code
CVE-2024-2404
CVE-2024-21111
CVE-2024-28627
CVE-2024-4073
information disclosure
CVE-2024-32780
CVE-2024-4040
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
1
2
NEXT »