Vulmon
Recent Vulnerabilities
Research Posts
Trends
Blog
About
Contact
Vulmon Alerts
By Relevance
By Risk Score
By Publish Date
modbus tcp firmware vulnerabilities and exploits
(subscribe to this query)
10
CVSSv2
CVE-2016-7112
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < ...
Siemens En100 Ethernet Module Firmware
7.8
CVSSv2
CVE-2016-7113
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < ...
Siemens En100 Ethernet Module Firmware 4.28
10
CVSSv2
CVE-2011-4861
The modbus_125_handler function in the Schneider Electric Quantum Ethernet Module on the NOE 771 device (aka the Quantum 140NOE771* module) allows remote malicious users to install arbitrary firmware updates via a MODBUS 125 function code to TCP port 502.
Schneider-electric Quantum Ethernet Module 140noe77101
Schneider-electric Quantum Ethernet Module 140noe77111
Schneider-electric Quantum Ethernet Module 140noe77100
5
CVSSv2
CVE-2019-6845
A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information when transferring applications to the controller using Modbus ...
Schneider-electric Modicon M580 Firmware
Schneider-electric Modicon M340 Firmware
Schneider-electric Tsxmcpc002m Firmware
Schneider-electric Tsxmcpc512k Firmware
Schneider-electric Tsxmfpp001m Firmware
Schneider-electric Tsxmfpp002m Firmware
Schneider-electric Tsxmfpp004m Firmware
Schneider-electric Tsxmfpp512k Firmware
Schneider-electric Tsxmrpc001m Firmware
Schneider-electric Tsxmrpc002m Firmware
Schneider-electric Tsxmrpc003m Firmware
Schneider-electric Tsxmrpc007m Firmware
Schneider-electric Tsxmrpc01m7 Firmware
Schneider-electric Tsxmrpc768k Firmware
Schneider-electric Tsxmrpf004m Firmware
Schneider-electric Tsxmrpf008m Firmware
Schneider-electric Tsxmfp0128p2 Firmware
Schneider-electric Tsxmfp064p2 Firmware
Schneider-electric Tsxmfpp224k Firmware
Schneider-electric Tsxmfpp384k Firmware
Schneider-electric Tsxmrpc448k Firmware
Schneider-electric Tsxmrpp224k Firmware
7.8
CVSSv2
CVE-2013-2784
Triangle Research International (aka Tri) Nano-10 PLC devices with firmware before r81 use an incorrect algorithm for bounds checking of data in Modbus/TCP packets, which allows remote malicious users to cause a denial of service (networking outage) via a crafted packet to TCP po...
Triplc Nano-10 Plc Firmware
Triplc Nano-10 Plc -
1 EDB exploit
5
CVSSv2
CVE-2016-4784
A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < ...
Siemens Siprotec Firmware -
Siemens Siprotec Firmware 4.26
5
CVSSv2
CVE-2016-4785
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < ...
Siemens Siprotec Firmware 4.26
Siemens Siprotec Firmware -
7.8
CVSSv2
CVE-2022-28613
A vulnerability in the HCI Modbus TCP COMPONENT of Hitachi Energy RTU500 series CMU Firmware that is caused by the validation error in the length information carried in MBAP header allows an malicious user to reboot the device by sending a special crafted message. This issue affe...
Abb Rtu500 Firmware
Hitachienergy Rtu500 Firmware
7.8
CVSSv2
CVE-2013-5741
Triangle Research International (aka Tri) Nano-10 PLC devices with firmware r81 and previous versions do not properly handle large length values in MODBUS data, which allows remote malicious users to cause a denial of service (transition to the interrupt state) via a crafted pack...
Triplc Nano-10 Plc Firmware R80
Triplc Nano-10 Plc Firmware
Triplc Nano-10 Plc -
9
CVSSv2
CVE-2016-7114
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < ...
Siemens En100 Ethernet Module Firmware 4.28
CVSSv2
CVSSv2
CVSSv3
VMScore
Recommendations:
deserialization
CVE-2024-4040
cross-site scripting
CVE-2023-25790
CVE-2024-2961
XML external entity
CVE-2024-26926
CVE-2024-32806
CVE-2024-32711
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
1
2
NEXT »