Vulmon
Recent Vulnerabilities
Research Posts
Trends
Blog
About
Contact
Vulmon Alerts
By Relevance
By Risk Score
By Publish Date
schneider-electric somachine basic vulnerabilities and exploits
(subscribe to this query)
187
VMScore
CVE-2018-7822
An Incorrect Default Permissions (CWE-276) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause unauthorized access to SoMachine Basic resource files when logged on the system hosting S...
Schneider-electric Somachine Basic
Schneider-electric Modicon M221 Firmware
445
VMScore
CVE-2018-7823
A Environment (CWE-2) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause remote launch of SoMachine Basic when sending crafted ethernet message.
Schneider-electric Somachine Basic
Schneider-electric Modicon M221 Firmware
445
VMScore
CVE-2018-7821
An Environment (CWE-2) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause cycle time impact when flooding the M221 ethernet interface while the Ethernet/IP adapter is activated.
Schneider-electric Somachine Basic
Schneider-electric Modicon M221 Firmware
445
VMScore
CVE-2018-7783
Schneider Electric SoMachine Basic prior to v1.6 SP1 suffers from an XML External Entity (XXE) vulnerability using the DTD parameter entities technique resulting in disclosure and retrieval of arbitrary data on the affected node via out-of-band (OOB) attack. The vulnerability is ...
Schneider-electric Somachine Basic
668
VMScore
CVE-2020-7489
A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') vulnerability exists on EcoStruxure Machine Expert – Basic or SoMachine Basic programming software (versions in security notification). The result of this ...
Schneider-electric Ecostruxure Machine Expert
Schneider-electric Somachine Basic
Schneider-electric Modicon M100 Firmware
Schneider-electric Modicon M200 Firmware
Schneider-electric Modicon M221 Firmware
668
VMScore
CVE-2017-7574
Schneider Electric SoMachine Basic 1.4 SP1 and Schneider Electric Modicon TM221CE16R 1.3.3.3 devices have a hardcoded-key vulnerability. The Project Protection feature is used to prevent unauthorized users from opening an XML protected project file, by prompting the user for a pa...
Schneider-electric Modicon Tm221ce16r Firmware 1.3.3.3
Schneider-electric Somachine 1.4
VMScore
CVSSv2
CVSSv3
VMScore
Recommendations:
CVE-2024-32976
CVE-2024-33557
CVE-2024-36801
CVE-2024-35654
authentication bypass
CVE-2024-24919
CSRF
code execution
CVE-2024-27348
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started