siemens simatic pcs 7 7.1 vulnerabilities and exploits
(subscribe to this query)
7.8
CVSSv3
CVE-2010-2772
Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568.
Siemens Simatic Wincc 6.2
Siemens Simatic Wincc 7.0
Siemens Simatic Pcs 7 7.1
Siemens Simatic Pcs 7 6.0
Siemens Simatic Pcs 7 6.1
Siemens Simatic Pcs 7 7.0
2 Github repositories
7.5
CVSSv3
CVE-2018-4832
A vulnerability has been identified in OpenPCS 7 V7.1 and previous versions (All versions), OpenPCS 7 V8.0 (All versions), OpenPCS 7 V8.1 (All versions < V8.1 Upd5), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd1), SIMATIC BATCH V7.1 and previous ve...
Siemens Openpcs 7 9.0
Siemens Openpcs 7 8.0
Siemens Openpcs 7 8.2
Siemens Openpcs 7
Siemens Openpcs 7 8.1
Siemens Simatic Batch 8.1
Siemens Simatic Batch 8.0
Siemens Simatic Batch 9.0
Siemens Simatic Batch 7.1
Siemens Simatic Batch 8.2
Siemens Simatic Net Pc 15
Siemens Simatic Net Pc
Siemens Simatic Pcs 7
Siemens Simatic Pcs 7 8.1
Siemens Simatic Pcs 7 8.0
Siemens Simatic Pcs 7 9.0
Siemens Simatic Pcs 7 8.2
Siemens Simatic Route Control
Siemens Simatic Route Control 8.0
Siemens Simatic Route Control 8.1
Siemens Simatic Route Control 9.0
Siemens Simatic Wincc Runtime Professional 14
1 Article
NA
CVE-2014-8552
The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote malicious users to read arbitrary files via crafted packets.
Siemens Simatic Tiaportal 13.0
Siemens Simatic Wincc 7.2
Siemens Simatic Pcs7 8.0
Siemens Simatic Pcs7 7.1
Siemens Simatic Pcs 7 7.1
Siemens Simatic Wincc 7.0
Siemens Simatic Pcs7 8.1
Siemens Simatic Wincc 7.3
NA
CVE-2014-8551
The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote malicious users to execute arbitrary code via crafted packets.
Siemens Simatic Tiaportal 13.0
Siemens Simatic Wincc 7.2
Siemens Simatic Pcs7 8.0
Siemens Simatic Pcs7 7.1
Siemens Simatic Pcs 7 7.1
Siemens Simatic Wincc 7.0
Siemens Simatic Pcs7 8.1
Siemens Simatic Wincc 7.3
CVSSv3
CVSSv2
CVSSv3
VMScore
Recommendations:
type confusion
IMAP
CVE-2024-36103
CVE-2024-28995
CVE-2024-37325
CVE-2024-30078
CVE-2024-30082
SQL injection
CVE-2024-30052
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started