CVE-2021-37206
A vulnerability has been identified in SIPROTEC 5 relays with CPU variants CP050 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP100 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP300 (All versions < V8.80). Received webpackets are not proper...
Siemens Siprotec 5 With Cpu Variant Cp050
Siemens Siprotec 5 With Cpu Variant Cp100
Siemens Siprotec 5 With Cpu Variant Cp300
668
VMScore
CVE-2021-33719
A vulnerability has been identified in SIPROTEC 5 relays with CPU variants CP050 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP100 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP300 (All versions < V8.80). Specially crafted packets sent to ...
Siemens Siprotec 5 With Cpu Variant Cp050
Siemens Siprotec 5 With Cpu Variant Cp100
Siemens Siprotec 5 With Cpu Variant Cp300
445
VMScore
CVE-2021-33720
A vulnerability has been identified in SIPROTEC 5 relays with CPU variants CP050 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP100 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP300 (All versions < V8.80). Specially crafted packets sent to ...
Siemens Siprotec 5 With Cpu Variant Cp050
Siemens Siprotec 5 With Cpu Variant Cp100
Siemens Siprotec 5 With Cpu Variant Cp300
383
VMScore
CVE-2018-16563
A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.35), Firmware variant MODBUS TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104...
Siemens Siprotec 5 With Cpu Variant Cp100
Siemens Siprotec 5 With Cpu Variant Cp300
Siemens Siprotec 5 With Cpu Variant Cp200
Siemens En100 Ethernet Module With Firmware Variant Modbus Tcp -
Siemens En100 Ethernet Module Firmware -
Siemens En100 Ethernet Module With Firmware Variant Profinet Io -
Siemens En100 Ethernet Module With Firmware Variant Iec104 -
Siemens En100 Ethernet Module With Firmware Variant Dnp3 Tcp -
Siemens En100 Ethernet Module With Firmware Variant Iec 61850 4.35
694
VMScore
CVE-2018-11451
A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.33), Firmware variant PROFINET IO for EN100 Ethernet module (All versions), Firmware variant Modbus TCP for EN100 Ethernet module (All versions), Firmware variant DNP...
Siemens Dnp3 Tcp Firmware -
Siemens Modbus Tcp Firmware -
Siemens Profinet Io Firmware -
Siemens Iec 61850 Firmware
Siemens Iec104 Firmware -
Siemens Cp100 Firmware
Siemens Cp300 Firmware
Siemens Cp200 Firmware -
VMScore
CVSSv2
CVSSv3
VMScore
Recommendations:
CVE-2023-7073
CVE-2024-5496
CVE-2024-5495
XPath injection
bypass
CVE-2024-30043
CVE-2024-24919
denial of service
CVE-2024-35468
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started