Vulmon
Recent Vulnerabilities
Product List
Research Posts
Trends
Blog
About
Contact
Vulmon Alerts
By Relevance
By Risk Score
By Publish Date
sun storedge enterprise backup software 7.2 vulnerabilities and exploits
(subscribe to this query)
NA
CVE-2005-3658
Multiple heap-based buffer overflows in EMC Legato NetWorker 7.1.x prior to 7.1.4 and 7.2.x prior to 7.2.1.Build.314, and other products such as Sun Solstice Backup (SBU) 6.0 and 6.1 and StorEdge Enterprise Backup Software (EBS) 7.1 up to and including 7.2L, allow remote maliciou...
Emc Legato Networker 7.1.1
Emc Legato Networker 7.2
Emc Legato Networker 7.1.3
Emc Legato Networker 7.2 Build172
Emc Legato Networker 7.1.2
Emc Legato Networker 7.2.1
NA
CVE-2005-3659
nsrd.exe in EMC Legato NetWorker 7.1.x prior to 7.1.4 and 7.2.x prior to 7.2.1.Build.314, and other products such as Sun Solstice Backup (SBU) 6.0 and 6.1 and StorEdge Enterprise Backup Software (EBS) 7.1 up to and including 7.2L, allows remote malicious users to cause a denial o...
Emc Legato Networker 7.2
Emc Legato Networker 7.2 Build172
Emc Legato Networker 7.2.1
NA
CVE-2005-0359
The Legato PortMapper in EMC Legato NetWorker, Sun Solstice Backup 6.0 and 6.1, and StorEdge Enterprise Backup 7.0 up to and including 7.2 does not restrict access to the pmap_set and pmap_unset commands, which allows remote malicious users to (1) cause a denial of service by usi...
Emc Legato Networker 6.0
Emc Legato Networker 7.2
Emc Legato Networker 4.2.2
Sun Storedge Enterprise Backup Software 7.0
Sun Storedge Enterprise Backup Software 7.1
Sun Storedge Enterprise Backup Software 7.2
Sun Solstice Backup 6.1
Emc Legato Networker 7.13
Sun Solstice Backup 6.0
Emc Legato Networker 6.1
NA
CVE-2005-0357
EMC Legato NetWorker, Sun Solstice Backup 6.0 and 6.1, and StorEdge Enterprise Backup 7.0 up to and including 7.2 rely on AUTH_UNIX authentication, which relies on user ID for authentication and allows remote malicious users to bypass authentication and gain privileges by spoofin...
Emc Legato Networker 6.0
Emc Legato Networker 7.2
Emc Legato Networker 4.2.2
Sun Storedge Enterprise Backup Software 7.0
Sun Storedge Enterprise Backup Software 7.1
Sun Storedge Enterprise Backup Software 7.2
Sun Solstice Backup 6.1
Emc Legato Networker 7.13
Sun Solstice Backup 6.0
Emc Legato Networker 6.1
NA
CVE-2005-0358
EMC Legato NetWorker, Solstice Backup 6.0 and 6.1, and StorEdge Enterprise Backup 6.0 up to and including 7.2 do not properly verify authentication tokens, which allows remote malicious users to gain privileges by modifying an authentication token.
Emc Legato Networker 6.0
Emc Legato Networker 7.2
Emc Legato Networker 4.2.2
Sun Storedge Enterprise Backup Software 7.0
Sun Storedge Enterprise Backup Software 7.1
Sun Storedge Enterprise Backup Software 7.2
Sun Solstice Backup 6.1
Emc Legato Networker 7.13
Sun Solstice Backup 6.0
Emc Legato Networker 6.1
CVSSv3
CVSSv2
CVSSv3
VMScore
Recommendations:
type confusion
IMAP
CVE-2024-36103
CVE-2024-28995
CVE-2024-37325
CVE-2024-30078
CVE-2024-30082
SQL injection
CVE-2024-30052
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started