abb opc server vulnerabilities and exploits
(subscribe to this query)
685
VMScore
CVE-2012-1801
Multiple stack-based buffer overflows in (1) COM and (2) ActiveX controls in ABB WebWare Server, WebWare SDK, Interlink Module, S4 OPC Server, QuickTeach, RobotStudio S4, and RobotStudio Lite allow remote malicious users to execute arbitrary code via crafted input data.
Abb Interlink Module -
Abb Webware Sdk -
Abb S4 Opc Server -
Abb Quickteach -
Abb Robotstudio Lite -
Abb Robotstudio S4 -
Abb Webware Server -
578
VMScore
CVE-2021-22284
Incorrect Permission Assignment for Critical Resource vulnerability in OPC Server for AC 800M allows an malicious user to execute arbitrary code in the node running the AC800M OPC Server.
Abb Opc Server For Ac 800m
890
VMScore
CVE-2012-0245
Multiple stack-based buffer overflows in RobNetScanHost.exe in ABB Robot Communications Runtime prior to 5.14.02, as used in ABB Interlink Module, IRC5 OPC Server, PC SDK, PickMaster 3 and 5, RobView 5, RobotStudio, WebWare SDK, and WebWare Server, allow remote malicious users to...
Abb Robotstudio -
Abb Pickmaster 3 -
Abb Interlink Module -
Abb Pc Sdk -
Abb Webware Sdk -
Abb Irc5 Opc Server -
Abb Pickmaster 5 -
Abb Webware Server -
Abb Robview 5 -
Abb Robot Communications Runtime
NA
CVE-2023-2685
A vulnerability was found in AO-OPC server versions mentioned above. As the directory information for the service entry is not enclosed in quotation marks, potential attackers could possibly call up another application than the AO-OPC server by starting the service. The service m...
Abb Ao-opc
668
VMScore
CVE-2020-8479
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus ...
Abb Control Builder Safe 1.1
Abb Control Builder Safe 1.0
Abb 800xa System 5.1
Abb Control Builder Safe 2.0
Abb Compact Hmi 6.0.1-1
Abb Compact Hmi 6.0.3-2
Abb 800xa System 6.0
Abb 800xa System 6.0.1
Abb 800xa System 6.0.3
Abb 800xa System 6.1
Abb Compact Hmi 5.1
187
VMScore
CVE-2020-8475
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus ...
Abb Control Builder Safe 1.1
Abb Control Builder Safe 1.0
Abb 800xa System 5.1
Abb Control Builder Safe 2.0
Abb Compact Hmi 6.0.1-1
Abb Compact Hmi 6.0.3-2
Abb 800xa System 6.0
Abb 800xa System 6.0.1
Abb 800xa System 6.0.3
Abb 800xa System 6.0.3.3
Abb 800xa System 6.1
Abb Compact Hmi 5.1
445
VMScore
CVE-2020-8476
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus ...
Abb Control Builder Safe 1.1
Abb Control Builder Safe 1.0
Abb 800xa System 5.1
Abb Control Builder Safe 2.0
Abb Compact Hmi 6.0.1-1
Abb Compact Hmi 6.0.3-2
Abb 800xa System 6.0
Abb 800xa System 6.0.1
Abb 800xa System 6.0.3
Abb 800xa System 6.0.3.3
Abb 800xa System 6.1
Abb Compact Hmi 5.1
187
VMScore
CVE-2020-8478
Insufficient protection of the inter-process communication functions in ABB System 800xA products OPC Server for AC 800M, MMS Server for AC 800M and Base Software for SoftControl (all published versions) enables an attacker authenticated on the local system to inject data, affect...
Abb Mms Server
Abb Opc Server
Abb Base Software
409
VMScore
CVE-2020-8471
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus ...
Abb 800xa System 5.1
Abb Compact Hmi 5.1
Abb Control Builder Safe 1.0
Abb Control Builder Safe 1.1
187
VMScore
CVE-2016-4524
ABB PCM600 prior to 2.7 improperly stores OPC Server IEC61850 passwords in unspecified temporary circumstances, which allows local users to obtain sensitive information via unknown vectors.
Abb Pcm600
VMScore