Vulmon
Recent Vulnerabilities
Research Posts
Trends
Blog
About
Contact
Vulmon Alerts
By Relevance
By Risk Score
By Publish Date
interactive graphical scada system vulnerabilities and exploits
(subscribe to this query)
10
CVSSv2
CVE-2013-0657
Stack-based buffer overflow in Schneider Electric Interactive Graphical SCADA System (IGSS) 10 and previous versions allows remote malicious users to execute arbitrary code by sending TCP port-12397 data that does not comply with a protocol.
Schneider-electric Interactive Graphical Scada System
Schneider-electric Interactive Graphical Scada System 9.0
2 EDB exploits
10
CVSSv2
CVE-2011-2959
Stack-based buffer overflow in the Open Database Connectivity (ODBC) service (Odbcixv9se.exe) in 7-Technologies Interactive Graphical SCADA System (IGSS) 9 and previous versions allows remote malicious users to cause a denial of service (crash) and possibly execute arbitrary code...
7t Igss 2.0
7t Igss 8
7t Igss
7t Igss 7
7t Igss 6
7t Igss 5.1
7t Igss 4.1
7t Igss 5.0
7t Igss 3.0
10
CVSSv2
CVE-2011-2214
Unspecified vulnerability in the Open Database Connectivity (ODBC) component in 7T Interactive Graphical SCADA System (IGSS) prior to 9.0.0.11143 allows remote malicious users to execute arbitrary code via a crafted packet to TCP port 20222, which triggers memory corruption relat...
7t Igss 9
7t Igss 8
7t Igss
10
CVSSv2
CVE-2011-1565
Directory traversal vulnerability in IGSSdataServer.exe 9.00.00.11063 and previous versions in 7-Technologies Interactive Graphical SCADA System (IGSS) allows remote malicious users to (1) read (opcode 0x3) or (2) create or write (opcode 0x2) arbitrary files via ..\ (dot dot back...
7t Igss
1 EDB exploit
10
CVSSv2
CVE-2011-1566
Directory traversal vulnerability in dc.exe 9.00.00.11059 and previous versions in 7-Technologies Interactive Graphical SCADA System (IGSS) allows remote malicious users to execute arbitrary programs via ..\ (dot dot backslash) sequences in opcodes (1) 0xa and (2) 0x17 to TCP por...
7t Igss
2 EDB exploits
10
CVSSv2
CVE-2011-1567
Multiple stack-based buffer overflows in IGSSdataServer.exe 9.00.00.11063 and previous versions in 7-Technologies Interactive Graphical SCADA System (IGSS) allow remote malicious users to cause a denial of service (crash) and possibly execute arbitrary code via crafted (1) ListAl...
7t Igss
3 EDB exploits
10
CVSSv2
CVE-2011-1568
Format string vulnerability in the logText function in shmemmgr9.dll in IGSSdataServer.exe 9.00.00.11074, and 9.00.00.11063 and previous versions, in 7-Technologies Interactive Graphical SCADA System (IGSS) allows remote malicious users to cause a denial of service and possibly e...
7t Igss
1 EDB exploit
9.3
CVSSv2
CVE-2021-22709
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in loss of data or remote code execution when malicious CGF (Config...
Schneider-electric Interactive Graphical Scada System
9.3
CVSSv2
CVE-2021-22711
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in arbitrary read or write conditions when malicious CGF (Configura...
Schneider-electric Interactive Graphical Scada System
9.3
CVSSv2
CVE-2021-22710
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could cause remote code execution when malicious CGF (Configuration Group File) ...
Schneider-electric Interactive Graphical Scada System
CVSSv2
CVSSv2
CVSSv3
VMScore
Recommendations:
authentication bypass
CVE-2024-30043
camera
CVE-2023-40404
CVE-2024-2793
client side
CVE-2024-4469
CVE-2024-3565
CVE-2024-29825
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
1
2
3
4
5
NEXT »