philips patient information center ix c.02 vulnerabilities and exploits
(subscribe to this query)
5.5
CVSSv3
CVE-2021-43552
The use of a hard-coded cryptographic key significantly increases the possibility encrypted data may be recovered from the Patient Information Center iX (PIC iX) Versions B.02, C.02, and C.03.
Philips Patient Information Center Ix B.02
Philips Patient Information Center Ix C.02
Philips Patient Information Center Ix C.03
6.8
CVSSv3
CVE-2020-16212
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource. The application on the surveillance station operates in kiosk mode, which is vuln...
Philips Patient Information Center Ix B.02
Philips Patient Information Center Ix C.02
Philips Patient Information Center Ix C.03
3.5
CVSSv3
CVE-2020-16218
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is then used as a webpage and served to other users. Successful exploitation could lead to un...
Philips Patient Information Center Ix B.02
Philips Patient Information Center Ix C.02
Philips Patient Information Center Ix C.03
5
CVSSv3
CVE-2020-16214
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software saves user-provided information into a comma-separated value (CSV) file, but it does not neutralize or incorrectly neutralizes special elements that could be interpreted as a command when the file is...
Philips Patient Information Center Ix B.02
Philips Patient Information Center Ix C.02
Philips Patient Information Center Ix C.03
6.5
CVSSv3
CVE-2021-43548
Patient Information Center iX (PIC iX) Versions C.02 and C.03 receives input or data, but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.
Philips Patient Information Center Ix C.02
Philips Patient Information Center Ix C.03
6.5
CVSSv3
CVE-2020-16224
In Patient Information Center iX (PICiX) Versions C.02, C.03, the software parses a formatted message or structure but does not handle or incorrectly handles a length field that is inconsistent with the actual length of the associated data, causing the application on the surveill...
Philips Patient Information Center Ix C.02
Philips Patient Information Center Ix C.03
6.5
CVSSv3
CVE-2021-43550
The use of a broken or risky cryptographic algorithm is an unnecessary risk that may result in the exposure of sensitive information, which affects the communications between Patient Information Center iX (PIC iX) Versions C.02 and C.03 and Efficia CM Series Revisions A.01 to C.0...
Philips Patient Information Center Ix C.02
Philips Patient Information Center Ix C.03
Philips Efficia Cm Firmware 4.0
Philips Efficia Cm Firmware
8.8
CVSSv3
CVE-2020-16222
In Patient Information Center iX (PICiX) Version B.02, C.02, C.03, and PerformanceBridge Focal Point Version A.01, when an actor claims to have a given identity, the software does not prove or insufficiently proves the claim is correct.
Philips Performancebridge Focal Point A.01
Philips Patient Information Center Ix B.02
Philips Patient Information Center Ix C.02
Philips Patient Information Center Ix C.03
4.3
CVSSv3
CVE-2020-16220
In Patient Information Center iX (PICiX) Versions C.02, C.03, PerformanceBridge Focal Point Version A.01, the product receives input that is expected to be well-formed (i.e., to comply with a certain syntax) but it does not validate or incorrectly validates that the input complie...
Philips Performancebridge Focal Point A.01
Philips Patient Information Center Ix B.02
Philips Patient Information Center Ix C.02
Philips Patient Information Center Ix C.03
6.5
CVSSv3
CVE-2020-16216
In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750, MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior, the product receives input or data but does not validate or incorrectly validates that the input has the properties required to process the...
Philips Performancebridge Focal Point A.01
Philips Patient Information Center Ix B.02
Philips Patient Information Center Ix C.02
Philips Patient Information Center Ix C.03
Philips Intellivue Mp2-mp90 Firmware -
Philips Intellivue Mx100 Firmware -
Philips Intellivue Mx400 Firmware -
Philips Intellivue Mx850 Firmware -
Philips Intellivue X2 Firmware -
Philips Intellivue X3 Firmware -
Philips Intellivue Mx800 Firmware -
Philips Intellivue Mx750 Firmware -
Philips Intellivue Mx700 Firmware -
Philips Intellivue Mx600 Firmware -
Philips Intellivue Mx550 Firmware -
CVSSv3
CVSSv2
CVSSv3
VMScore
Recommendations:
CVE-2024-4761
command injection
CVE-2024-3676
IDOR
CVE-2024-30039
CVE-2024-32113
CVE-2024-30049
CVE-2024-4776
SQL injection
Vulnerability Notification Service