schneider-electric ap9630 firmware vulnerabilities and exploits
(subscribe to this query)
445
VMScore
CVE-2018-7820
A Credentials Management CWE-255 vulnerability exists in the APC UPS Network Management Card 2 AOS v6.5.6, which could cause Remote Monitoring Credentials to be viewed in plaintext when Remote Monitoring is enabled, and then disabled.
Schneider-electric Ap9630 Firmware
Schneider-electric Smart-ups Srt 5kva Firmware
Schneider-electric Ap9631 Firmware
Schneider-electric Ap9635 Firmware
445
VMScore
CVE-2021-22815
A CWE-200: Information Exposure vulnerability exists which could cause the troubleshooting archive to be accessed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630...
Schneider-electric Network Management Card 2 Firmware
Schneider-electric Network Management Card 3 Firmware
383
VMScore
CVE-2021-22810
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to a delete pol...
Schneider-electric Network Management Card 2 Firmware
Schneider-electric Network Management Card 3 Firmware
383
VMScore
CVE-2021-22811
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause script execution when the request of a privileged account accessing the vulnerable web page is intercepted. Affected Products: 1-Phase Un...
Schneider-electric Network Management Card 2 Firmware
Schneider-electric Network Management Card 3 Firmware
383
VMScore
CVE-2021-22812
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC. Affected Products: 1-Ph...
Schneider-electric Network Management Card 2 Firmware
Schneider-electric Network Management Card 3 Firmware
383
VMScore
CVE-2021-22813
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit poli...
Schneider-electric Network Management Card 2 Firmware
Schneider-electric Network Management Card 3 Firmware
383
VMScore
CVE-2021-22814
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists which could cause arbritrary script execution when a malicious file is read and displayed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) u...
Schneider-electric Network Management Card 2 Firmware
Schneider-electric Network Management Card 3 Firmware
VMScore
CVSSv2
CVSSv3
VMScore
Recommendations:
buffer overflow
type confusion
server-side request forgery
CVE-2024-38440
CVE-2024-27801
CVE-2024-5868
CVE-2024-0582
CVE-2024-37643
CVE-2024-3105