Vulmon
Recent Vulnerabilities
Product List
Research Posts
Trends
Blog
About
Contact
Vulmon Alerts
By Relevance
By Risk Score
By Publish Date
schneider-electric ion8800 - vulnerabilities and exploits
(subscribe to this query)
8.8
CVSSv3
CVE-2016-5809
An issue exists on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. There is no CSRF Token generated to authenticate the user during a session. Successful exploitation of this vulnera...
Schneider-electric Ion7600 -
Schneider-electric Ion7300 -
Schneider-electric Ion8650 -
Schneider-electric Ion7500 -
Schneider-electric Ion5000 -
Schneider-electric Ion8800 -
1 EDB exploit
9.8
CVSSv3
CVE-2016-5815
An issue exists on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. No authentication is configured by default. An unauthorized user can access the device management portal and make c...
Schneider-electric Ion7600 -
Schneider-electric Ion7300 -
Schneider-electric Ion8650 -
Schneider-electric Ion7500 -
Schneider-electric Ion5000 -
Schneider-electric Ion8800 -
4.9
CVSSv3
CVE-2023-5984
A CWE-494 Download of Code Without Integrity Check vulnerability exists that could allow modified firmware to be uploaded when an authorized admin user begins a firmware update procedure which could result in full control over the device.
Schneider-electric Ion8650 Firmware
Schneider-electric Ion8800 Firmware
4.8
CVSSv3
CVE-2023-5985
A CWE-79 Improper Neutralization of Input During Web Page Generation vulnerability exists that could cause compromise of a user’s browser when an attacker with admin privileges has modified system values.
Schneider-electric Ion8650 Firmware
Schneider-electric Ion8800 Firmware
9.8
CVSSv3
CVE-2022-46680
A CWE-319: Cleartext transmission of sensitive information vulnerability exists that could cause disclosure of sensitive information, denial of service, or modification of data if an attacker is able to intercept network traffic.
Schneider-electric Powerlogic Ion9000 Firmware
Schneider-electric Powerlogic Ion7400 Firmware
Schneider-electric Powerlogic Pm8000 Firmware
Schneider-electric Powerlogic Ion8650 Firmware -
Schneider-electric Powerlogic Ion8800 Firmware -
4.5
CVSSv3
CVE-2021-22701
A CWE-352: Cross-Site Request Forgery vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause a user to perform an unintended action on the target device when using...
Schneider-electric Powerlogic Ion7400 Firmware
Schneider-electric Powerlogic Ion7650 Firmware
Schneider-electric Powerlogic Ion8600 Firmware
Schneider-electric Powerlogic Ion8650 Firmware
Schneider-electric Powerlogic Ion8800 Firmware
Schneider-electric Powerlogic Ion9000 Firmware
Schneider-electric Powerlogic Pm8000 Firmware
Schneider-electric Powerlogic Ion8300 Firmware
Schneider-electric Powerlogic Ion8400 Firmware
Schneider-electric Powerlogic Ion8500 Firmware
7.5
CVSSv3
CVE-2021-22703
A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious a...
Schneider-electric Powerlogic Ion7400 Firmware
Schneider-electric Powerlogic Ion7650 Firmware
Schneider-electric Powerlogic Ion8600 Firmware
Schneider-electric Powerlogic Ion8650 Firmware
Schneider-electric Powerlogic Ion8800 Firmware
Schneider-electric Powerlogic Ion9000 Firmware
Schneider-electric Powerlogic Pm8000 Firmware
Schneider-electric Powerlogic Ion8300 Firmware
Schneider-electric Powerlogic Ion8400 Firmware
Schneider-electric Powerlogic Ion8500 Firmware
7.5
CVSSv3
CVE-2021-22713
A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION8650, ION8800, ION7650, ION7700/73xx, and ION83xx/84xx/85xx/8600 (see security notifcation for affected versions), which could cause the meter to reboot.
Schneider-electric Powerlogic Ion8650 Firmware
Schneider-electric Powerlogic Ion8800 Firmware
Schneider-electric Powerlogic Ion7550 Firmware
Schneider-electric Powerlogic Ion7650 Firmware
Schneider-electric Powerlogic Ion7700 Firmware
Schneider-electric Powerlogic Ion7300 Firmware
Schneider-electric Powerlogic Ion8300 Firmware
Schneider-electric Powerlogic Ion8400 Firmware
Schneider-electric Powerlogic Ion8500 Firmware
Schneider-electric Powerlogic Ion8600 Firmware
Schneider-electric Ion7650 Firmware
7.5
CVSSv3
CVE-2021-22702
A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION7700/73xx, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when...
Schneider-electric Powerlogic Ion7400 Firmware
Schneider-electric Powerlogic Ion7650 Firmware
Schneider-electric Powerlogic Ion7700 Firmware
Schneider-electric Powerlogic Ion7300 Firmware
Schneider-electric Powerlogic Ion8600 Firmware
Schneider-electric Powerlogic Ion8650 Firmware
Schneider-electric Powerlogic Ion8800 Firmware
Schneider-electric Powerlogic Ion9000 Firmware
Schneider-electric Powerlogic Pm8000 Firmware
Schneider-electric Powerlogic Ion8300 Firmware
Schneider-electric Powerlogic Ion8400 Firmware
Schneider-electric Powerlogic Ion8500 Firmware
CVSSv3
CVSSv2
CVSSv3
VMScore
Recommendations:
CVE-2024-27802
template injection
CVE-2024-0044
code injection
CVE-2024-35474
CVE-2024-27857
CVE-2024-23251
CVE-2024-23692
physical
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results