abb opc server vulnerabilities and exploits
(subscribe to this query)
9.8
CVSSv3
CVE-2020-8481
For ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5....
Abb 800xa System 5.1
9.8
CVSSv3
CVE-2020-8479
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus ...
Abb Control Builder Safe 1.1
Abb Control Builder Safe 1.0
Abb 800xa System 5.1
Abb Control Builder Safe 2.0
Abb Compact Hmi 6.0.1-1
Abb Compact Hmi 6.0.3-2
Abb 800xa System 6.0
Abb 800xa System 6.0.1
Abb 800xa System 6.0.3
Abb 800xa System 6.1
Abb Compact Hmi 5.1
8.8
CVSSv3
CVE-2021-22284
Incorrect Permission Assignment for Critical Resource vulnerability in OPC Server for AC 800M allows an malicious user to execute arbitrary code in the node running the AC800M OPC Server.
Abb Opc Server For Ac 800m
7.8
CVSSv3
CVE-2020-8471
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus ...
Abb Control Builder Safe 1.1
Abb Control Builder Safe 1.0
Abb 800xa System 5.1
Abb Compact Hmi 5.1
7.8
CVSSv3
CVE-2020-8472
Insufficient folder permissions used by system functions in ABB System 800xA products OPCServer for AC800M (versions 6.0 and previous versions) and Control Builder M Professional, MMSServer for AC800M, Base Software for SoftControl (version 6.1 and previous versions) allow low pr...
Abb Control Builder M
Abb Mms Server
Abb Opc Server
Abb Base Software
7.5
CVSSv3
CVE-2020-8475
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus ...
Abb Control Builder Safe 1.1
Abb Control Builder Safe 1.0
Abb 800xa System 5.1
Abb Control Builder Safe 2.0
Abb Compact Hmi 6.0.1-1
Abb Compact Hmi 6.0.3-2
Abb 800xa System 6.0
Abb 800xa System 6.0.1
Abb 800xa System 6.0.3
Abb 800xa System 6.0.3.3
Abb 800xa System 6.1
Abb Compact Hmi 5.1
7.5
CVSSv3
CVE-2020-8476
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus ...
Abb Control Builder Safe 1.1
Abb Control Builder Safe 1.0
Abb 800xa System 5.1
Abb Control Builder Safe 2.0
Abb Compact Hmi 6.0.1-1
Abb Compact Hmi 6.0.3-2
Abb 800xa System 6.0
Abb 800xa System 6.0.1
Abb 800xa System 6.0.3
Abb 800xa System 6.0.3.3
Abb 800xa System 6.1
Abb Compact Hmi 5.1
6.5
CVSSv3
CVE-2016-4524
ABB PCM600 prior to 2.7 improperly stores OPC Server IEC61850 passwords in unspecified temporary circumstances, which allows local users to obtain sensitive information via unknown vectors.
Abb Pcm600
6.3
CVSSv3
CVE-2023-2685
A vulnerability was found in AO-OPC server versions mentioned above. As the directory information for the service entry is not enclosed in quotation marks, potential attackers could possibly call up another application than the AO-OPC server by starting the service. The service m...
Abb Ao-opc
3.3
CVSSv3
CVE-2020-8478
Insufficient protection of the inter-process communication functions in ABB System 800xA products OPC Server for AC 800M, MMS Server for AC 800M and Base Software for SoftControl (all published versions) enables an attacker authenticated on the local system to inject data, affect...
Abb Mms Server
Abb Opc Server
Abb Base Software
CVSSv3
CVSSv2
CVSSv3
VMScore
Recommendations:
buffer overflow
type confusion
server-side request forgery
CVE-2024-38440
CVE-2024-27801
CVE-2024-5868
CVE-2024-0582
CVE-2024-37643
CVE-2024-3105