9.8
CVSSv3
CVE-2018-14805
ABB eSOMS version 6.0.2 may allow unauthorized access to the system when LDAP is set to allow anonymous authentication, and specific key values within the eSOMS web.config file are present. Both conditions are required to exploit this vulnerability.
Hitachienergy Esoms 6.0.2
7.6
CVSSv3
CVE-2019-19094
Lack of input checks for SQL queries in ABB eSOMS versions 3.9 to 6.0.3 might allow an attacker SQL injection attacks against the backend database.
Hitachienergy Esoms
7.5
CVSSv3
CVE-2021-35527
Password autocomplete vulnerability in the web application password field of Hitachi ABB Power Grids eSOMS allows malicious user to gain access to user credentials that are stored by the browser. This issue affects: Hitachi ABB Power Grids eSOMS version 6.3 and prior versions.
Hitachienergy Esoms
7.5
CVSSv3
CVE-2021-26845
Information Exposure vulnerability in Hitachi ABB Power Grids eSOMS allows unauthorized user to gain access to report data if the URL used to access the report is discovered. This issue affects: Hitachi ABB Power Grids eSOMS 6.0 versions before 6.0.4.2.2; 6.1 versions before 6.1....
Hitachienergy Esoms
7.5
CVSSv3
CVE-2019-19097
ABB eSOMS versions 4.0 to 6.0.3 accept connections using medium strength ciphers. If a connection is enabled using such a cipher, an attacker might be able to eavesdrop and/or intercept the connection.
Hitachienergy Esoms
6.5
CVSSv3
CVE-2019-19001
For ABB eSOMS versions 4.0 to 6.0.2, the X-Frame-Options header is not configured in HTTP response. This can potentially allow 'ClickJacking' attacks where an attacker can frame parts of the application on a malicious web site, revealing sensitive user information such ...
Hitachienergy Esoms
6.5
CVSSv3
CVE-2019-19093
eSOMS versions 4.0 to 6.0.3 do not enforce password complexity settings, potentially resulting in lower access security due to insecure user passwords.
Hitachienergy Esoms
6.5
CVSSv3
CVE-2019-19000
For ABB eSOMS 4.0 to 6.0.3, the Cache-Control and Pragma HTTP header(s) have not been properly configured within the application response. This can potentially allow browsers and proxies to cache sensitive information.
Hitachienergy Esoms
6.1
CVSSv3
CVE-2019-19089
For ABB eSOMS versions 4.0 to 6.0.3, the X-Content-Type-Options Header is missing in the HTTP response, potentially causing the response body to be interpreted and displayed as different content type other than declared. A possible attack scenario would be unauthorized code execu...
Hitachienergy Esoms
6.1
CVSSv3
CVE-2019-19096
The Redis data structure component used in ABB eSOMS versions 6.0 to 6.0.2 stores credentials in clear text. If an attacker has file system access, this can potentially compromise the credentials' confidentiality.
Hitachienergy Esoms
CVSSv3
CVSSv2
CVSSv3
VMScore
Recommendations:
CVE-2024-33572
CVE-2024-24919
CVE-2024-0230
CVE-2024-32714
HTML injection
local file inclusion
CVE-2024-31098
CVE-2024-31244
privilege
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
1
2
NEXT »