Vulmon
Recent Vulnerabilities
Product List
Research Posts
Trends
Blog
About
Contact
Vulmon Alerts
By Relevance
By Risk Score
By Publish Date
schneider-electric ecostruxure operator terminal expert vulnerabilities and exploits
(subscribe to this query)
7.8
CVSSv3
CVE-2020-7493
A CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) which could cause malicious code execution when opening ...
Schneider-electric Ecostruxure Operator Terminal Expert
Schneider-electric Ecostruxure Operator Terminal Expert 3.1
7.8
CVSSv3
CVE-2020-7494
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) which could cause malicious code execution when opening the pr...
Schneider-electric Ecostruxure Operator Terminal Expert
Schneider-electric Ecostruxure Operator Terminal Expert 3.1
5.5
CVSSv3
CVE-2020-7495
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability during zip file extraction exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) which could cause unauthorized writ...
Schneider-electric Ecostruxure Operator Terminal Expert
Schneider-electric Ecostruxure Operator Terminal Expert 3.1
9.8
CVSSv3
CVE-2020-7497
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)which could cause arbitrary application execution when the comp...
Schneider-electric Ecostruxure Operator Terminal Expert
Schneider-electric Ecostruxure Operator Terminal Expert 3.1
7.8
CVSSv3
CVE-2023-1049
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause execution of malicious code when an unsuspicious user loads a project file from the local filesystem into the HMI.
Schneider-electric Ecostruxure Operator Terminal Expert 3.3
Schneider-electric Ecostruxure Operator Terminal Expert
Schneider-electric Pro-face Blue 3.3
Schneider-electric Pro-face Blue
7.8
CVSSv3
CVE-2022-41666
A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists that allows adversaries with local user privileges to load a malicious DLL which could lead to execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or pr...
Schneider-electric Ecostruxure Operator Terminal Expert 3.3
Schneider-electric Ecostruxure Operator Terminal Expert
Schneider-electric Pro-face Blue 3.3
Schneider-electric Pro-face Blue
7.8
CVSSv3
CVE-2022-41667
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that allows adversaries with local user privileges to load a malicious DLL which could lead to execution of malicious code. Affected Products: EcoStruxure Opera...
Schneider-electric Ecostruxure Operator Terminal Expert
Schneider-electric Pro-face Blue
Schneider-electric Pro-face Blue 3.3
Schneider-electric Ecostruxure Operator Terminal Expert 3.3
7.8
CVSSv3
CVE-2022-41668
A CWE-704: Incorrect Project Conversion vulnerability exists that allows adversaries with local user privileges to load a project file from an adversary-controlled network share which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Ex...
Schneider-electric Ecostruxure Operator Terminal Expert
Schneider-electric Pro-face Blue
Schneider-electric Pro-face Blue 3.3
Schneider-electric Ecostruxure Operator Terminal Expert 3.3
7.8
CVSSv3
CVE-2022-41669
A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists in the SGIUtility component that allows adversaries with local user privileges to load a malicious DLL which could result in execution of malicious code. Affected Products: EcoStruxure Operator Termi...
Schneider-electric Ecostruxure Operator Terminal Expert 3.3
Schneider-electric Ecostruxure Operator Terminal Expert
Schneider-electric Pro-face Blue 3.3
Schneider-electric Pro-face Blue
7.8
CVSSv3
CVE-2022-41670
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in the SGIUtility component that allows adversaries with local user privileges to load malicious DLL which could result in execution of malicious code. Affected...
Schneider-electric Ecostruxure Operator Terminal Expert 3.3
Schneider-electric Ecostruxure Operator Terminal Expert
Schneider-electric Pro-face Blue 3.3
Schneider-electric Pro-face Blue
CVSSv3
CVSSv2
CVSSv3
VMScore
Recommendations:
buffer overflow
type confusion
server-side request forgery
CVE-2024-38440
CVE-2024-27801
CVE-2024-5868
CVE-2024-0582
CVE-2024-37643
CVE-2024-3105
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
1
2
NEXT »