CVE-2017-12069
An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code prior to 2017-03-21 and Local Discovery Server (LDS) prior to 1.03.367. Among the affected products are Siemens SIMATIC PCS7 (All versions V8.1 and previous versions), SIMATIC WinCC (All versions < ...
Siemens Simatic Pcs7
Siemens Wincc
Ocpfoundation Ua .net
Ocpfoundation Local Discovery Server
6.4
CVSSv3
CVE-2016-7165
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (All versions < V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions < V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIM...
Siemens Simatic Wincc 7.2
Siemens Simatic Wincc Runtime -
Siemens Simatic Wincc (tia Portal)
Siemens Simit 9.0
Siemens Simatic Wincc
Siemens Simatic Pcs7 8.0
Siemens Simatic Step 7 (tia Portal)
Siemens Simatic Pcs 7
Siemens Sinema Remote Connect -
Siemens Simatic Wincc 7.4
Siemens Simatic Step 7
Siemens Simatic Winac Rtx 2010 -
Siemens Simatic Pcs7 8.1
Siemens Softnet Security Client
Siemens Simatic Net Pc Software
Siemens Simatic It Production Suite -
Siemens Telecontrol Basic
Siemens Security Configuration Tool -
Siemens Simatic Wincc (tia Portal) -
Siemens Primary Setup Tool -
Siemens Sinema Server
Siemens Simatic Wincc 7.3
4.9
CVSSv3
CVE-2017-14023
An Improper Input Validation issue exists in Siemens SIMATIC PCS 7 V8.1 prior to V8.1 SP1 with WinCC V7.3 Upd 13, and V8.2 all versions. The improper input validation vulnerability has been identified, which may allow an authenticated remote attacker who is a member of the admini...
Siemens Simatic Wincc 7.3
Siemens Simatic Pcs7 8.1
Siemens Simatic Pcs7 8.2
NA
CVE-2014-8552
The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote malicious users to read arbitrary files via crafted packets.
Siemens Simatic Tiaportal 13.0
Siemens Simatic Wincc 7.2
Siemens Simatic Pcs7 8.0
Siemens Simatic Pcs7 7.1
Siemens Simatic Pcs 7 7.1
Siemens Simatic Wincc 7.0
Siemens Simatic Pcs7 8.1
Siemens Simatic Wincc 7.3
NA
CVE-2014-8551
The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote malicious users to execute arbitrary code via crafted packets.
Siemens Simatic Tiaportal 13.0
Siemens Simatic Wincc 7.2
Siemens Simatic Pcs7 8.0
Siemens Simatic Pcs7 7.1
Siemens Simatic Pcs 7 7.1
Siemens Simatic Wincc 7.0
Siemens Simatic Pcs7 8.1
Siemens Simatic Wincc 7.3
NA
CVE-2014-4682
The WebNavigator server in Siemens SIMATIC WinCC prior to 7.3, as used in PCS7 and other products, allows remote malicious users to obtain sensitive information via an HTTP request.
Siemens Wincc 7.1
Siemens Simatic Pcs7 8.0
Siemens Wincc 6.0
Siemens Simatic Pcs7 7.1
Siemens Wincc 7.0
Siemens Simatic Pcs7
Siemens Wincc 5.0
Siemens Wincc
NA
CVE-2014-4683
The WebNavigator server in Siemens SIMATIC WinCC prior to 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a (1) HTTP or (2) HTTPS request.
Siemens Wincc 7.1
Siemens Simatic Pcs7 8.0
Siemens Wincc 6.0
Siemens Simatic Pcs7 7.1
Siemens Wincc 7.0
Siemens Simatic Pcs7
Siemens Wincc 5.0
Siemens Wincc
NA
CVE-2014-4684
The database server in Siemens SIMATIC WinCC prior to 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a request to TCP port 1433.
Siemens Wincc 7.1
Siemens Simatic Pcs7 8.0
Siemens Wincc 6.0
Siemens Simatic Pcs7 7.1
Siemens Wincc 7.0
Siemens Simatic Pcs7
Siemens Wincc 5.0
Siemens Wincc
NA
CVE-2014-4685
Siemens SIMATIC WinCC prior to 7.3, as used in PCS7 and other products, allows local users to gain privileges by leveraging weak system-object access control.
Siemens Wincc 7.1
Siemens Simatic Pcs7 8.0
Siemens Wincc 6.0
Siemens Simatic Pcs7 7.1
Siemens Wincc 7.0
Siemens Simatic Pcs7
Siemens Wincc 5.0
Siemens Wincc
NA
CVE-2014-4686
The Project administration application in Siemens SIMATIC WinCC prior to 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote malicious users to obtain sensitive information by extracting this key from another product installation and then ...
Siemens Wincc 7.1
Siemens Simatic Pcs7 8.0
Siemens Wincc 6.0
Siemens Simatic Pcs7 7.1
Siemens Wincc 7.0
Siemens Simatic Pcs7
Siemens Wincc 5.0
Siemens Wincc
CVSSv3
CVSSv2
CVSSv3
VMScore
Recommendations:
type confusion
IMAP
CVE-2024-36103
CVE-2024-28995
CVE-2024-37325
CVE-2024-30078
CVE-2024-30082
SQL injection
CVE-2024-30052
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
1
2
3
NEXT »