Vulmon
Recent Vulnerabilities
Research Posts
Trends
Blog
About
Contact
Vulmon Alerts
By Relevance
By Risk Score
By Publish Date
applied-risk.com vulnerabilities and exploits
(subscribe to this query)
7.5
CVSSv3
CVE-2019-7254
Linear eMerge E3-Series devices allow File Inclusion.
Nortekcontrol Linear Emerge Essential Firmware
Nortekcontrol Linear Emerge Elite Firmware
8.8
CVSSv3
CVE-2019-7258
Linear eMerge E3-Series devices allow Privilege Escalation.
Nortekcontrol Linear Emerge Essential Firmware
Nortekcontrol Linear Emerge Elite Firmware
8.8
CVSSv3
CVE-2019-7259
Linear eMerge E3-Series devices allow Authorization Bypass with Information Disclosure.
Nortekcontrol Linear Emerge Essential Firmware
Nortekcontrol Linear Emerge Elite Firmware
9.8
CVSSv3
CVE-2019-7261
Linear eMerge E3-Series devices have Hard-coded Credentials.
Nortekcontrol Linear Emerge Essential Firmware
Nortekcontrol Linear Emerge Elite Firmware
8.8
CVSSv3
CVE-2019-7262
Linear eMerge E3-Series devices allow Cross-Site Request Forgery (CSRF).
Nortekcontrol Linear Emerge Essential Firmware
Nortekcontrol Linear Emerge Elite Firmware
6.1
CVSSv3
CVE-2019-7275
Optergy Proton/Enterprise devices allow Open Redirect.
Optergy Proton
Optergy Enterprise
9.8
CVSSv3
CVE-2019-7667
Prima Systems FlexAir, Versions 2.3.38 and prior. The application generates database backup files with a predictable name, and an attacker can use brute force to identify the database backup file name. A malicious actor can exploit this issue to download the database file and dis...
Primasystems Flexair
7.2
CVSSv3
CVE-2019-7670
Prima Systems FlexAir, Versions 2.3.38 and prior. The application incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component, which could allow malicious users to execute commands directly on the operating system.
Primasystems Flexair
6.1
CVSSv3
CVE-2019-10846
Computrols CBAS 18.0.0 allows Unauthenticated Reflected Cross-Site Scripting vulnerabilities in the login page and password reset page via the username GET parameter.
Computrols Computrols Building Automation System
8.8
CVSSv3
CVE-2019-10852
Computrols CBAS 18.0.0 allows Authenticated Blind SQL Injection via the id GET parameter, as demonstrated by the index.php?m=servers&a=start_pulling&id= substring.
Computrols Computrols Building Automation Software
CVSSv3
CVSSv2
CVSSv3
VMScore
Recommendations:
CVE-2022-48693
CVE-2024-30851
CVE-2024-34460
CVE-2024-2887
local
CVE-2024-27956
remote code execution
CVE-2024-34475
privilege
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
1
2
3
4
NEXT »