interactive graphical scada system vulnerabilities and exploits
(subscribe to this query)
NA
CVE-2013-0657
Stack-based buffer overflow in Schneider Electric Interactive Graphical SCADA System (IGSS) 10 and previous versions allows remote malicious users to execute arbitrary code by sending TCP port-12397 data that does not comply with a protocol.
Schneider-electric Interactive Graphical Scada System
Schneider-electric Interactive Graphical Scada System 9.0
2 EDB exploits
7.5
CVSSv3
CVE-2020-7478
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a remote unauthenticated malicious user to read arbitrary files from the IGSS server PC on an unrestricted or shared netwo...
Schneider-electric Interactive Graphical Scada System
7.8
CVSSv3
CVE-2020-7479
A CWE-306: Missing Authentication for Critical Function vulnerability exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a local user to execute processes that otherwise require escalation privileges when sending local network commands to the ...
Schneider-electric Interactive Graphical Scada System
7.8
CVSSv3
CVE-2020-7550
A CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 and prior that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definit...
Schneider-electric Interactive Graphical Scada System
7.8
CVSSv3
CVE-2020-7551
A CWE-787: Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247, that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
Schneider-electric Interactive Graphical Scada System
7.8
CVSSv3
CVE-2020-7552
A CWE-787: Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247, that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
Schneider-electric Interactive Graphical Scada System
7.8
CVSSv3
CVE-2020-7553
A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
Schneider-electric Interactive Graphical Scada System
7.8
CVSSv3
CVE-2020-7554
A CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
Schneider-electric Interactive Graphical Scada System
7.8
CVSSv3
CVE-2020-7555
A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
Schneider-electric Interactive Graphical Scada System
7.8
CVSSv3
CVE-2020-7556
A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
Schneider-electric Interactive Graphical Scada System
CVSSv3
CVSSv2
CVSSv3
VMScore
Recommendations:
authentication bypass
CVE-2024-30043
camera
CVE-2023-40404
CVE-2024-2793
client side
CVE-2024-4469
CVE-2024-3565
CVE-2024-29825
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
1
2
3
4
5
6
NEXT »