Vulmon
Recent Vulnerabilities
Research Posts
Trends
Blog
About
Contact
Vulmon Alerts
By Relevance
By Risk Score
By Publish Date
schneider-electric interactive graphical scada system vulnerabilities and exploits
(subscribe to this query)
NA
CVE-2013-0657
Stack-based buffer overflow in Schneider Electric Interactive Graphical SCADA System (IGSS) 10 and previous versions allows remote malicious users to execute arbitrary code by sending TCP port-12397 data that does not comply with a protocol.
Schneider-electric Interactive Graphical Scada System
Schneider-electric Interactive Graphical Scada System 9.0
2 EDB exploits
7.8
CVSSv3
CVE-2021-22754
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to lack of proper validation of user-supplied data, when a malicious CGF file is imported to IGSS Definition.
Schneider-electric Interactive Graphical Scada System
9.8
CVSSv3
CVE-2022-32529
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted log data request messages. Affected Products: IGSS Data Server - IGSSda...
Schneider-electric Interactive Graphical Scada System
7.8
CVSSv3
CVE-2019-6827
A CWE-787: Out-of-bounds Write vulnerability exists in Interactive Graphical SCADA System (IGSS), Version 14 and prior, which could cause a software crash when data in the mdb database is manipulated.
Schneider-electric Interactive Graphical Scada System
7.8
CVSSv3
CVE-2017-6033
A DLL Hijacking issue exists in Schneider Electric Interactive Graphical SCADA System (IGSS) Software, Version 12 and previous versions. The software will execute a malicious file if it is named the same as a legitimate file and placed in a location that is earlier in the search ...
Schneider-electric Interactive Graphical Scada System
7.8
CVSSv3
CVE-2021-22709
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in loss of data or remote code execution when malicious CGF (Config...
Schneider-electric Interactive Graphical Scada System
7.8
CVSSv3
CVE-2021-22710
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could cause remote code execution when malicious CGF (Configuration Group File) ...
Schneider-electric Interactive Graphical Scada System
7.8
CVSSv3
CVE-2021-22711
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in arbitrary read or write conditions when malicious CGF (Configura...
Schneider-electric Interactive Graphical Scada System
7.8
CVSSv3
CVE-2021-22712
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in arbitrary read or write conditions when malicious CGF (Configura...
Schneider-electric Interactive Graphical Scada System
7.8
CVSSv3
CVE-2023-4516
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the IGSS Update Service that could allow a local malicious user to change update source, potentially leading to remote code execution when the attacker force an update containing malicious content.
Schneider-electric Interactive Graphical Scada System
CVSSv3
CVSSv2
CVSSv3
VMScore
Recommendations:
CVE-2023-52710
arbitrary
CVE-2024-5272
CVE-2024-2961
brute force
remote
CVE-2024-32944
CVE-2024-36241
CVE-2024-5274
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
1
2
3
4
5
6
NEXT »