struxureware data center expert vulnerabilities and exploits
(subscribe to this query)
NA
CVE-2023-37199
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause remote code execution when an admin user on DCE tampers with backups which are then manually restored.
Schneider-electric Struxureware Data Center Expert
NA
CVE-2023-37196
A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command ('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to access unauthorized content, change, or delete content, or perform unauthorized act...
Schneider-electric Struxureware Data Center Expert
NA
CVE-2023-37197
A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command ('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to access unauthorized content, change, or delete content, or perform unauthorized act...
Schneider-electric Struxureware Data Center Expert
NA
CVE-2023-37198
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause remote code execution when an admin user on DCE uploads or tampers with install packages.
Schneider-electric Struxureware Data Center Expert
NA
CVE-2023-25548
A CWE-863: Incorrect Authorization vulnerability exists that could allow access to device credentials on specific DCE endpoints not being properly secured when a hacker is using a low privileged user. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
Schneider-electric Struxureware Data Center Expert
NA
CVE-2023-25551
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists on a DCE file upload endpoint when tampering with parameters over HTTP. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
Schneider-electric Struxureware Data Center Expert
NA
CVE-2023-25552
A CWE-862: Missing Authorization vulnerability exists that could allow viewing of unauthorized content, changes or deleting of content, or performing unauthorized functions when tampering the Device File Transfer settings on DCE endpoints. Affected products: StruxureWare Data Ce...
Schneider-electric Struxureware Data Center Expert
NA
CVE-2023-25554
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that allows a local privilege escalation on the appliance when a maliciously crafted Operating System command is entered on the device. Affected pr...
Schneider-electric Struxureware Data Center Expert
NA
CVE-2023-25555
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow a user that knows the credentials to execute unprivileged shell commands on the appliance over SSH. Affected products: StruxureWar...
Schneider-electric Struxureware Data Center Expert
NA
CVE-2023-25547
A CWE-863: Incorrect Authorization vulnerability exists that could allow remote code execution on upload and install packages when a hacker is using a low privileged user account. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
Schneider-electric Struxureware Data Center Expert
CVSSv2
CVSSv2
CVSSv3
VMScore
Recommendations:
inject
CVE-2024-34001
CVE-2024-37018
LFI
CVE-2024-1275
CVE-2024-1086
CSRF
CVE-2024-31030
CVE-2024-24919