Vulmon
Recent Vulnerabilities
Research Posts
Trends
Blog
About
Contact
Vulmon Alerts
By Relevance
By Risk Score
By Publish Date
deltaww vulnerabilities and exploits
(subscribe to this query)
3.5
CVSSv2
CVE-2021-38428
Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter name of the API schedule, which may allow an malicious user to remotely execute code.
Deltaww Dialink
4.6
CVSSv2
CVE-2021-38422
Delta Electronics DIALink versions 1.2.4.0 and prior stores sensitive information in cleartext, which may allow an malicious user to have extensive access to the application directory and escalate privileges.
Deltaww Dialink
6.8
CVSSv2
CVE-2021-38424
The tag interface of Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to an attacker injecting formulas into the tag data. Those formulas may then be executed when it is opened with a spreadsheet application.
Deltaww Dialink
10
CVSSv2
CVE-2022-26887
Delta Electronics DIAEnergie (All versions before 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_loopmapHandler.ashx. This allows an malicious user to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands.
Deltaww Diaenergie
10
CVSSv2
CVE-2021-38390
A Blind SQL injection vulnerability exists in the /DataHandler/HandlerEnergyType.ashx endpoint of Delta Electronics DIAEnergie Version 1.7.5 and prior. The application does not properly validate the user-controlled value supplied through the parameter egyid before using it as par...
Deltaww Diaenergie
10
CVSSv2
CVE-2021-38391
A Blind SQL injection vulnerability exists in the /DataHandler/AM/AM_Handler.ashx endpoint of Delta Electronics DIAEnergie Version 1.7.5 and prior. The application does not properly validate the user-controlled value supplied through the parameter type before using it as part of ...
Deltaww Diaenergie
10
CVSSv2
CVE-2021-38393
A Blind SQL injection vulnerability exists in the /DataHandler/HandlerAlarmGroup.ashx endpoint of Delta Electronics DIAEnergie Version 1.7.5 and prior. The application does not properly validate the user-controlled value supplied through the parameter agid before using it as part...
Deltaww Diaenergie
6.8
CVSSv2
CVE-2021-38402
Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when parsing specific project files. This could lead to a stack-based buffer overflow while trying to copy to a buffer during font string handling. An attacker could leverage this...
Deltaww Dopsoft
3.5
CVSSv2
CVE-2021-38403
Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter supplier of the API maintenance, which may allow an malicious user to remotely execute code.
Deltaww Dialink
6.8
CVSSv2
CVE-2021-38404
Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when parsing specific project files. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current...
Deltaww Dopsoft
CVSSv2
CVSSv2
CVSSv3
VMScore
Recommendations:
CVE-2024-4367
CVE-2024-3611
CVE-2024-4947
CVE-2024-32988
CVE-2020-35165
local file inclusion
CVE-2024-4980
bypass
malicious code
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
« PREV
5
6
7
8
9
10