Vulmon
Recent Vulnerabilities
Product List
Research Posts
Trends
Blog
About
Contact
Vulmon Alerts
By Relevance
By Risk Score
By Publish Date
deltaww infrasuite device master vulnerabilities and exploits
(subscribe to this query)
9.8
CVSSv3
CVE-2023-1133
Delta Electronics InfraSuite Device Master versions before 1.0.5 contain a vulnerability in which the Device-status service listens on port 10100/ UDP by default. The service accepts the unverified UDP packets and deserializes the content, which could allow an unauthenticated mal...
Deltaww Infrasuite Device Master
9.8
CVSSv3
CVE-2022-40202
The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper authentication. An attacker could provide malicious serialized objects which, when deserialized, could activate an opcode for a backup scheduling function without...
Deltaww Infrasuite Device Master
9.8
CVSSv3
CVE-2022-41657
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided data already serialized into memory to be used in file operation application programmable interfaces (APIs). This could create arbitrary files, which could be used in API operations a...
Deltaww Infrasuite Device Master
9.1
CVSSv3
CVE-2022-41629
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an malicious user to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify...
Deltaww Infrasuite Device Master
7.5
CVSSv3
CVE-2022-41688
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups. An attacker could provide malicious serialized objects that could run these functions without authentication to create a new user ...
Deltaww Infrasuite Device Master
7.5
CVSSv3
CVE-2022-41776
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to trigger the WriteConfiguration method, which could allow an malicious user to provide new values for user configuration files such as UserListInfo.xml. This could lead to the c...
Deltaww Infrasuite Device Master
8.8
CVSSv3
CVE-2022-41778
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-DataCollect service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserial...
Deltaww Infrasuite Device Master
9.8
CVSSv3
CVE-2022-41779
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verification. If the device connects to an attacker-controlled server, the attacker could send maliciously crafted packets that would be deserialized and executed, ...
Deltaww Infrasuite Device Master
9.8
CVSSv3
CVE-2022-38142
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-Gateway service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserializat...
Deltaww Infrasuite Device Master
7.5
CVSSv3
CVE-2023-34316
?An attacker could bypass the latest Delta Electronics InfraSuite Device Master (versions before 1.0.7) patch, which could allow an malicious user to retrieve file contents.
Deltaww Infrasuite Device Master
CVSSv3
CVSSv2
CVSSv3
VMScore
Recommendations:
CVE-2024-0044
client side
CVE-2021-47601
deserialization
CVE-2024-34994
encryption
CVE-2021-47609
CVE-2024-37079
CVE-2024-38608
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
« PREV
1
2
3
4
NEXT »