Vulmon
Recent Vulnerabilities
Research Posts
Trends
Blog
About
Contact
Vulmon Alerts
By Relevance
By Risk Score
By Publish Date
ip security camera firmware vulnerabilities and exploits
(subscribe to this query)
5
CVSSv2
CVE-2013-2572
A Security Bypass vulnerability exists in TP-LINK IP Cameras TL-SC 3130, TL-SC 3130G, 3171G, 4171G, and 3130 1.6.18P12 due to default hard-coded credentials for the administrative Web interface, which could let a malicious user obtain unauthorized access to CGI files.
Tp-link Tl-sc 3130 Firmware
Tp-link Tl-sc 3130g Firmware
Tp-link Tl-sc 3171g Firmware
Tp-link Tl-sc 4171g Firmware
1 EDB exploit
10
CVSSv2
CVE-2015-8286
Zhuhai RaySharp firmware has a hardcoded root password, which makes it easier for remote malicious users to obtain access via a session on TCP port 23 or 9000.
Zhuhai Raysharp Firmware
10
CVSSv2
CVE-2013-2573
A Command Injection vulnerability exists in the ap parameter to the /cgi-bin/mft/wireless_mft.cgi file in TP-Link IP Cameras TL-SC 3130, TL-SC 3130G, 3171G. and 4171G 1.6.18P12s, which could let a malicious user execute arbitrary code.
Tp-link Tl-sc 3130g Firmware
Tp-link Tl-sc 3171g Firmware
Tp-link Tl-sc 4171g Firmware
1 EDB exploit
NA
CVE-2013-25703
Core Security Technologies Advisory - Zavio IP cameras based on firmware versions 1.6.03 and below suffer from bypass, hard-coded credential, and arbitrary command execution vulnerabilities.
NA
CVE-2013-15983
Core Security Technologies Advisory - Vivotek IP Cameras suffer from information leak, buffer overflow, authentication, path traversal, and command injection vulnerabilities. Vulnerable are Vivotek PT7135 IP camera with firmware 0300a, Vivotek PT7135 IP camera with firmware 0400a...
5
CVSSv2
CVE-2013-1596
An Authentication Bypass Vulnerability exists in Vivotek PT7135 IP Camera 0300a and 0400a via specially crafted RTSP packets to TCP port 554.
Vivotek Pt7135 Firmware 0300a
Vivotek Pt7135 Firmware 0400a
1 EDB exploit
8.3
CVSSv2
CVE-2020-3507
Multiple vulnerabilities in the Cisco Discovery Protocol implementation for Cisco Video Surveillance 8000 Series IP Cameras could allow an unauthenticated, adjacent malicious user to execute code remotely or cause a reload of an affected IP camera. These vulnerabilities are due t...
Cisco 8000p Ip Camera Firmware 1.0.9-1
Cisco 8020 Ip Camera Firmware 1.0.9-1
Cisco 8030 Ip Camera Firmware 1.0.9-1
Cisco 8070 Ip Camera Firmware 1.0.9-1
Cisco 8400 Ip Camera Firmware 1.0.9-1
Cisco 8620 Ip Camera Firmware 1.0.9-1
Cisco 8630 Ip Camera Firmware 1.0.9-1
Cisco 8930 Speed Dome Ip Camera Firmware 1.0.9-1
8.3
CVSSv2
CVE-2020-3506
Multiple vulnerabilities in the Cisco Discovery Protocol implementation for Cisco Video Surveillance 8000 Series IP Cameras could allow an unauthenticated, adjacent malicious user to execute code remotely or cause a reload of an affected IP camera. These vulnerabilities are due t...
Cisco 8000p Ip Camera Firmware 1.0.9-1
Cisco 8020 Ip Camera Firmware 1.0.9-1
Cisco 8030 Ip Camera Firmware 1.0.9-1
Cisco 8070 Ip Camera Firmware 1.0.9-1
Cisco 8400 Ip Camera Firmware 1.0.9-1
Cisco 8620 Ip Camera Firmware 1.0.9-1
Cisco 8630 Ip Camera Firmware 1.0.9-1
Cisco 8930 Speed Dome Ip Camera Firmware 1.0.9-1
4
CVSSv2
CVE-2013-1597
A Directory Traversal vulnerability exists in Vivotek PT7135 IP Cameras 0300a and 0400a via a specially crafted GET request, which could let a malicious user obtain user credentials.
Vivotek Pt7135 Firmware 0300a
Vivotek Pt7135 Firmware 0400a
1 EDB exploit
9
CVSSv2
CVE-2013-1598
A Command Injection vulnerability exists in Vivotek PT7135 IP Cameras 0300a and 0400a via the system.ntp parameter to the farseer.out binary file, which cold let a malicious user execute arbitrary code.
Vivotek Pt7135 Firmware 0300a
Vivotek Pt7135 Firmware 0400a
1 EDB exploit
CVSSv2
CVSSv2
CVSSv3
VMScore
Recommendations:
blind SQL injection
SSRF
buffer overflow
CVE-2023-28952
CVE-2023-41822
CVE-2024-27956
CVE-2023-7028
CVE-2024-34447
CVE-2024-34460
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
« PREV
1
2
3