Vulmon
Recent Vulnerabilities
Product List
Research Posts
Trends
Blog
About
Contact
Vulmon Alerts
By Relevance
By Risk Score
By Publish Date
schneider-electric somachine - vulnerabilities and exploits
(subscribe to this query)
8.8
CVSSv3
CVE-2017-7966
A DLL Hijacking vulnerability in the programming software in Schneider Electric's SoMachine HVAC v2.1.0 allows a remote malicious user to execute arbitrary code on the targeted system. The vulnerability exists due to the improper loading of a DLL.
Schneider-electric Somachine 2.1.0
7.8
CVSSv3
CVE-2019-6826
A CWE-426: Untrusted Search Path vulnerability exists in SoMachine HVAC v2.4.1 and previous versions versions, which could cause arbitrary code execution on the system running SoMachine HVAC when a malicious DLL library is loaded by the product.
Schneider-electric Somachine Hvac
7.5
CVSSv3
CVE-2018-7783
Schneider Electric SoMachine Basic prior to v1.6 SP1 suffers from an XML External Entity (XXE) vulnerability using the DTD parameter entities technique resulting in disclosure and retrieval of arbitrary data on the affected node via out-of-band (OOB) attack. The vulnerability is ...
Schneider-electric Somachine Basic
8.2
CVSSv3
CVE-2018-7798
A Insufficient Verification of Data Authenticity (CWE-345) vulnerability exists in the Modicon M221, all versions, which could cause a change of IPv4 configuration (IP address, mask and gateway) when remotely connected to the device.
Schneider-electric Somachine Basic
7.3
CVSSv3
CVE-2016-4529
An unspecified ActiveX control in Schneider Electric SoMachine HVAC Programming Software for M171/M172 Controllers prior to 2.1.0 allows remote malicious users to execute arbitrary code via unknown vectors, related to the INTERFACESAFE_FOR_UNTRUSTED_CALLER (aka safe for scripting...
Schneider-electric Somachine Hvac Firmware
7.3
CVSSv3
CVE-2017-7965
A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric's SoMachine HVAC v2.1.0 for Modicon M171/M172 Controller.
Schneider-electric Somachine Hvac 2.1.0
9.8
CVSSv3
CVE-2020-7489
A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') vulnerability exists on EcoStruxure Machine Expert – Basic or SoMachine Basic programming software (versions in security notification). The result of this ...
Schneider-electric Somachine Basic
Schneider-electric Ecostruxure Machine Expert
Schneider-electric Modicon M100 Firmware
Schneider-electric Modicon M200 Firmware
Schneider-electric Modicon M221 Firmware
CVSSv3
CVSSv2
CVSSv3
VMScore
Recommendations:
CVE-2024-37884
CVE-2024-6003
remote
brute force
information disclosure
CVE-2024-27801
CVE-2024-30078
CVE-2024-31870
CVE-2024-6042
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
« PREV
1
2