Vulmon
Recent Vulnerabilities
Research Posts
Trends
Blog
About
Contact
Vulmon Alerts
By Relevance
By Risk Score
By Publish Date
siemens simatic pcs7 7.1 vulnerabilities and exploits
(subscribe to this query)
5
CVSSv2
CVE-2014-4682
The WebNavigator server in Siemens SIMATIC WinCC prior to 7.3, as used in PCS7 and other products, allows remote malicious users to obtain sensitive information via an HTTP request.
Siemens Simatic Pcs7
Siemens Simatic Pcs7 8.0
Siemens Wincc 7.1
Siemens Wincc
Siemens Wincc 6.0
Siemens Wincc 7.0
Siemens Simatic Pcs7 7.1
Siemens Wincc 5.0
4.9
CVSSv2
CVE-2014-4683
The WebNavigator server in Siemens SIMATIC WinCC prior to 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a (1) HTTP or (2) HTTPS request.
Siemens Simatic Pcs7
Siemens Wincc 7.1
Siemens Wincc
Siemens Wincc 6.0
Siemens Wincc 7.0
Siemens Simatic Pcs7 8.0
Siemens Wincc 5.0
Siemens Simatic Pcs7 7.1
4.6
CVSSv2
CVE-2014-4685
Siemens SIMATIC WinCC prior to 7.3, as used in PCS7 and other products, allows local users to gain privileges by leveraging weak system-object access control.
Siemens Simatic Pcs7
Siemens Wincc 7.1
Siemens Wincc
Siemens Wincc 6.0
Siemens Simatic Pcs7 8.0
Siemens Wincc 5.0
Siemens Wincc 7.0
Siemens Simatic Pcs7 7.1
4
CVSSv2
CVE-2013-3959
The Web Navigator in Siemens WinCC prior to 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and previous versions and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerat...
Siemens Wincc 7.0
Siemens Wincc 7.1
Siemens Wincc
Siemens Simatic Pcs7 8.0
Siemens Simatic Pcs7
4
CVSSv2
CVE-2013-0676
Siemens WinCC prior to 7.2, as used in SIMATIC PCS7 prior to 8.0 SP1 and other products, does not properly assign privileges for the database containing WebNavigator credentials, which allows remote authenticated users to obtain sensitive information via a SQL query.
Siemens Wincc 7.0
Siemens Wincc 6.0
Siemens Wincc
Siemens Wincc 5.0
Siemens Simatic Pcs7 7.1
Siemens Simatic Pcs7
4
CVSSv2
CVE-2013-0679
Directory traversal vulnerability in the web server in Siemens WinCC prior to 7.2, as used in SIMATIC PCS7 prior to 8.0 SP1 and other products, allows remote authenticated users to read arbitrary files via vectors involving a query for a pathname.
Siemens Wincc 7.0
Siemens Wincc 6.0
Siemens Wincc
Siemens Wincc 5.0
Siemens Simatic Pcs7 7.1
Siemens Simatic Pcs7
CVSSv2
CVSSv2
CVSSv3
VMScore
Recommendations:
CVE-2024-23316
SQL injection
type confusion
CVE-2024-20697
CVE-2024-4344
local
CVE-2024-30043
CVE-2024-3821
CVE-2024-5041
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
« PREV
1
2