CVE-2014-4683
The WebNavigator server in Siemens SIMATIC WinCC prior to 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a (1) HTTP or (2) HTTPS request.
Siemens Simatic Pcs7
Siemens Wincc 7.1
Siemens Wincc
Siemens Wincc 6.0
Siemens Wincc 7.0
Siemens Simatic Pcs7 8.0
Siemens Wincc 5.0
Siemens Simatic Pcs7 7.1
409
VMScore
CVE-2014-4685
Siemens SIMATIC WinCC prior to 7.3, as used in PCS7 and other products, allows local users to gain privileges by leveraging weak system-object access control.
Siemens Simatic Pcs7
Siemens Wincc 7.1
Siemens Wincc
Siemens Wincc 6.0
Siemens Simatic Pcs7 8.0
Siemens Wincc 5.0
Siemens Wincc 7.0
Siemens Simatic Pcs7 7.1
605
VMScore
CVE-2014-4686
The Project administration application in Siemens SIMATIC WinCC prior to 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote malicious users to obtain sensitive information by extracting this key from another product installation and then ...
Siemens Wincc 7.1
Siemens Wincc
Siemens Wincc 6.0
Siemens Simatic Pcs7
Siemens Simatic Pcs7 7.1
Siemens Wincc 5.0
Siemens Wincc 7.0
Siemens Simatic Pcs7 8.0
445
VMScore
CVE-2014-4682
The WebNavigator server in Siemens SIMATIC WinCC prior to 7.3, as used in PCS7 and other products, allows remote malicious users to obtain sensitive information via an HTTP request.
Siemens Simatic Pcs7
Siemens Simatic Pcs7 8.0
Siemens Wincc 7.1
Siemens Wincc
Siemens Wincc 6.0
Siemens Wincc 7.0
Siemens Simatic Pcs7 7.1
Siemens Wincc 5.0
534
VMScore
CVE-2014-4684
The database server in Siemens SIMATIC WinCC prior to 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a request to TCP port 1433.
Siemens Simatic Pcs7
Siemens Wincc 7.1
Siemens Wincc
Siemens Wincc 6.0
Siemens Simatic Pcs7 7.1
Siemens Wincc 5.0
Siemens Wincc 7.0
Siemens Simatic Pcs7 8.0
615
VMScore
CVE-2010-2772
Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568.
Siemens Simatic Wincc 6.2
Siemens Simatic Wincc 7.0
Siemens Simatic Pcs 7 7.1
Siemens Simatic Pcs 7 6.0
Siemens Simatic Pcs 7 6.1
Siemens Simatic Pcs 7 7.0
2 Github repositories
642
VMScore
CVE-2014-0160
The (1) TLS and (2) DTLS implementations in OpenSSL 1.0.1 prior to 1.0.1g do not properly handle Heartbeat Extension packets, which allows remote malicious users to obtain sensitive information from process memory via crafted packets that trigger a buffer over-read, as demonstrat...
Openssl Openssl
Filezilla-project Filezilla Server
Siemens Application Processing Engine Firmware 2.0
Siemens Cp 1543-1 Firmware 1.1
Siemens Simatic S7-1500 Firmware 1.5
Siemens Simatic S7-1500t Firmware 1.5
Siemens Elan-8.2
Siemens Wincc Open Architecture 3.12
Intellian V100 Firmware 1.20
Intellian V100 Firmware 1.21
Intellian V100 Firmware 1.24
Intellian V60 Firmware 1.15
Intellian V60 Firmware 1.25
Mitel Micollab 6.0
Mitel Micollab 7.0
Mitel Micollab 7.1
Mitel Micollab 7.2
Mitel Micollab 7.3.0.104
Mitel Micollab 7.3
Mitel Mivoice 1.1.3.3
Mitel Mivoice 1.2.0.11
Mitel Mivoice 1.3.2.2
4 EDB exploits
2 Nmap scripts
307 Github repositories
4 Articles
VMScore
CVSSv2
CVSSv3
VMScore
Recommendations:
CVE-2024-4367
CVE-2024-35977
CVE-2023-49335
man-in-the-middle
CVE-2024-4947
CVE-2024-31714
memory leak
SQL
CVE-2024-35994
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
« PREV
1
2