struxureware data center expert vulnerabilities and exploits
(subscribe to this query)
NA
CVE-2023-25547
A CWE-863: Incorrect Authorization vulnerability exists that could allow remote code execution on upload and install packages when a hacker is using a low privileged user account. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
Schneider-electric Struxureware Data Center Expert
NA
CVE-2023-25553
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists on a DCE endpoint through the logging capabilities of the webserver. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
Schneider-electric Struxureware Data Center Expert
NA
CVE-2023-37196
A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command ('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to access unauthorized content, change, or delete content, or perform unauthorized act...
Schneider-electric Struxureware Data Center Expert
NA
CVE-2023-37197
A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command ('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to access unauthorized content, change, or delete content, or perform unauthorized act...
Schneider-electric Struxureware Data Center Expert
NA
CVE-2023-37199
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause remote code execution when an admin user on DCE tampers with backups which are then manually restored.
Schneider-electric Struxureware Data Center Expert
4
CVSSv2
CVE-2017-8371
Schneider Electric StruxureWare Data Center Expert prior to 7.4.0 uses cleartext RAM storage for passwords, which might allow remote malicious users to obtain sensitive information via unspecified vectors.
Schneider-electric Struxureware Data Center Expert
NA
CVE-2023-37198
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause remote code execution when an admin user on DCE uploads or tampers with install packages.
Schneider-electric Struxureware Data Center Expert
CVSSv2
CVSSv2
CVSSv3
VMScore
Recommendations:
CVE-2024-3581
reflected XSS
CVE-2024-26925
CVE-2024-27956
LFI
CVE-2024-3607
CVE-2024-3107
CVE-2024-3295
SQL