struxureware data center expert vulnerabilities and exploits
(subscribe to this query)
6.1
CVSSv3
CVE-2023-25553
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists on a DCE endpoint through the logging capabilities of the webserver. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
Schneider-electric Struxureware Data Center Expert
7.8
CVSSv3
CVE-2023-25554
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that allows a local privilege escalation on the appliance when a maliciously crafted Operating System command is entered on the device. Affected pr...
Schneider-electric Struxureware Data Center Expert
8.1
CVSSv3
CVE-2023-25555
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow a user that knows the credentials to execute unprivileged shell commands on the appliance over SSH. Affected products: StruxureWar...
Schneider-electric Struxureware Data Center Expert
8.8
CVSSv3
CVE-2023-37196
A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command ('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to access unauthorized content, change, or delete content, or perform unauthorized act...
Schneider-electric Struxureware Data Center Expert
8.8
CVSSv3
CVE-2023-37197
A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command ('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to access unauthorized content, change, or delete content, or perform unauthorized act...
Schneider-electric Struxureware Data Center Expert
7.2
CVSSv3
CVE-2023-37198
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause remote code execution when an admin user on DCE uploads or tampers with install packages.
Schneider-electric Struxureware Data Center Expert
7.2
CVSSv3
CVE-2023-37199
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause remote code execution when an admin user on DCE tampers with backups which are then manually restored.
Schneider-electric Struxureware Data Center Expert
CVSSv3
CVSSv2
CVSSv3
VMScore
Recommendations:
camera
bypass
CVE-2024-3592
CVE-2024-37383
CVE-2024-24919
CVE-2024-27822
CVE-2024-36788
CVE-2024-36789
man-in-the-middle
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
« PREV
1
2