Vulmon
Recent Vulnerabilities
Research Posts
Trends
Blog
About
Contact
Vulmon Alerts
By Relevance
By Risk Score
By Publish Date
intel data center manager vulnerabilities and exploits
(subscribe to this query)
4
CVSSv2
CVE-2020-8669
Improper input validation in the Intel(R) Data Center Manager Console before version 3.6.2 may allow an authenticated user to potentially enable information disclosure via network access.
Intel Data Center Manager
2.1
CVSSv2
CVE-2019-0103
Insufficient file protection in install routine for Intel(R) Data Center Manager SDK before version 5.0.2 may allow an authenticated user to potentially enable information disclosure via local access.
Intel Data Center Manager
4.6
CVSSv2
CVE-2019-0105
Insufficient file permissions checking in install routine for Intel(R) Data Center Manager SDK before version 5.0.2 may allow authenticated user to potentially enable escalation of privilege via local access.
Intel Data Center Manager
4.6
CVSSv2
CVE-2019-0107
Insufficient user prompt in install routine for Intel(R) Data Center Manager SDK before version 5.0.2 may allow a privileged user to potentially enable escalation of privilege via local access.
Intel Data Center Manager
4.6
CVSSv2
CVE-2019-0109
Improper folder permissions in Intel(R) Data Center Manager SDK before version 5.0.2 may allow an authenticated user to potentially enable escalation of privilege via local access.
Intel Data Center Manager
2.1
CVSSv2
CVE-2019-0112
Improper flow control in crypto routines for Intel(R) Data Center Manager SDK before version 5.0.2 may allow a privileged user to potentially enable a denial of service via local access.
Intel Data Center Manager
5.8
CVSSv2
CVE-2019-0102
Insufficient session authentication in web server for Intel(R) Data Center Manager SDK before version 5.0.2 may allow an unauthenticated user to potentially enable escalation of privilege via network access.
Intel Data Center Manager
2.1
CVSSv2
CVE-2019-0104
Insufficient file protection in uninstall routine for Intel(R) Data Center Manager SDK before version 5.0.2 may allow an authenticated user to potentially enable information disclosure via local access.
Intel Data Center Manager
4.6
CVSSv2
CVE-2019-0106
Insufficient run protection in install routine for Intel(R) Data Center Manager SDK before version 5.0.2 may allow a privileged user to potentially enable escalation of privilege via local access.
Intel Data Center Manager
2.1
CVSSv2
CVE-2019-0108
Improper file permissions for Intel(R) Data Center Manager SDK before version 5.0.2 may allow an authenticated user to potentially enable disclosure of information via local access.
Intel Data Center Manager
CVSSv2
CVSSv2
CVSSv3
VMScore
Recommendations:
CVE-2024-3380
CVE-2024-1694
local file inclusion
CVE-2024-5645
CVE-2024-24919
XSS
CVE-2024-36774
CVE-2024-21306
SQL
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
« PREV
1
2
3
4
NEXT »