(subscribe to this query)
7.8
CVSSv3
CVE-2021-40363
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and previous versions (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Upd...
Siemens Simatic Pcs 7
Siemens Simatic Wincc 7.4
Siemens Simatic Wincc 14.0.1
Siemens Simatic Wincc 13
Siemens Simatic Wincc 7.5
Siemens Simatic Wincc
Siemens Simatic Wincc 15.1
Siemens Simatic Pcs 7 9.0
Siemens Simatic Wincc 16
Siemens Simatic Wincc 15
Siemens Simatic Wincc 17
Siemens Simatic Pcs 7 9.1
7.8
CVSSv3
CVE-2018-11453
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions < V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All version...
Siemens Simatic Step 7 \\(tia Portal\\) 13.0
Siemens Simatic Wincc \\(tia Portal\\) 10.0
Siemens Simatic Wincc \\(tia Portal\\) 11.0
Siemens Simatic Wincc \\(tia Portal\\) 12.0
Siemens Simatic Wincc \\(tia Portal\\) 13.0
Siemens Simatic Wincc \\(tia Portal\\) 15.0
Siemens Simatic Step 7 \\(tia Portal\\) 11.0
Siemens Simatic Step 7 \\(tia Portal\\) 12.0
Siemens Simatic Step 7 \\(tia Portal\\) 14.0
Siemens Simatic Wincc \\(tia Portal\\) 14.0
Siemens Simatic Step 7 \\(tia Portal\\) 10.0
Siemens Simatic Step 7 \\(tia Portal\\) 15.0
7.8
CVSSv3
CVE-2010-2772
Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568.
Siemens Simatic Wincc 6.2
Siemens Simatic Wincc 7.0
Siemens Simatic Pcs 7 7.1
Siemens Simatic Pcs 7 6.0
Siemens Simatic Pcs 7 6.1
Siemens Simatic Pcs 7 7.0
2 Github repositories
7.7
CVSSv3
CVE-2021-40359
A vulnerability has been identified in OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd4), OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V8.2 (All versions), SIMATIC BATCH V9.0 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC NET PC Software V14 ...
Siemens Simatic Wincc
Siemens Simatic Wincc 7.5
Siemens Simatic Route Control 8.2
Siemens Simatic Net Pc 16
Siemens Simatic Route Control 9.0
Siemens Simatic Batch 9.0
Siemens Simatic Wincc 16
Siemens Simatic Wincc 17
Siemens Simatic Batch 8.2
Siemens Simatic Net Pc 15
Siemens Simatic Net Pc 14
Siemens Simatic Net Pc 17
Siemens Simatic Route Control 9.1
Siemens Simatic Batch 9.1
Siemens Simaticpcs 7
Siemens Simaticpcs 7 9.1
Siemens Simatic Wincc 15
7.5
CVSSv3
CVE-2021-40142
In OPC Foundation Local Discovery Server (LDS) prior to 1.04.402.463, remote attackers can cause a denial of service (DoS) by sending carefully crafted messages that lead to Access of a Memory Location After the End of a Buffer.
Opcfoundation Local Discover Server
Siemens Simatic Process Historian Opc Ua Server Firmware 2022
Siemens Simatic Process Historian Opc Ua Server Firmware
Siemens Simatic Wincc Runtime -
Siemens Simatic Wincc -
Siemens Simatic Net Pc 16
Siemens Simatic Net Pc 15
Siemens Simatic Net Pc 14
Siemens Telecontrol Server Basic 3.0
Siemens Simatic Net Pc 17
Siemens Simatic Wincc Unified Scada Runtime -
7.5
CVSSv3
CVE-2021-27383
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update...
Siemens Simatic Wincc Runtime Advanced
Siemens Simatic Wincc Runtime Advanced 16
Siemens Sinamics Sh150 Firmware
Siemens Sinamics Sm150i Firmware
Siemens Sinamics Gh150 Firmware
Siemens Sinamics Gl150 Firmware
Siemens Sinamics Gm150 Firmware
Siemens Sinamics Sl150 Firmware
Siemens Sinamics Sm120 Firmware
Siemens Sinamics Sm150 Firmware
Siemens Simatic Hmi Comfort Outdoor Panels 7\\\" Firmware
Siemens Simatic Hmi Comfort Outdoor Panels 7\\\" Firmware 16
Siemens Simatic Hmi Comfort Outdoor Panels 15\\\" Firmware
Siemens Simatic Hmi Comfort Outdoor Panels 15\\\" Firmware 16
Siemens Simatic Hmi Comfort Panels 4\\\" Firmware
Siemens Simatic Hmi Comfort Panels 4\\\" Firmware 16
Siemens Simatic Hmi Comfort Panels 22\\\" Firmware
Siemens Simatic Hmi Comfort Panels 22\\\" Firmware 16
Siemens Simatic Hmi Ktp Mobile Panels Ktp400f Firmware
Siemens Simatic Hmi Ktp Mobile Panels Ktp400f Firmware 16
Siemens Simatic Hmi Ktp Mobile Panels Ktp700 Firmware
Siemens Simatic Hmi Ktp Mobile Panels Ktp700 Firmware 16
7.5
CVSSv3
CVE-2021-27385
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update...
Siemens Simatic Wincc Runtime Advanced 16
Siemens Simatic Wincc Runtime Advanced
Siemens Sinamics Sh150 Firmware
Siemens Sinamics Sm150i Firmware
Siemens Sinamics Gh150 Firmware
Siemens Sinamics Gl150 Firmware
Siemens Sinamics Gm150 Firmware
Siemens Sinamics Sl150 Firmware
Siemens Sinamics Sm120 Firmware
Siemens Sinamics Sm150 Firmware
Siemens Simatic Hmi Comfort Outdoor Panels 7\\\" Firmware 16
Siemens Simatic Hmi Comfort Outdoor Panels 7\\\" Firmware
Siemens Simatic Hmi Comfort Outdoor Panels 15\\\" Firmware 16
Siemens Simatic Hmi Comfort Outdoor Panels 15\\\" Firmware
Siemens Simatic Hmi Comfort Panels 4\\\" Firmware 16
Siemens Simatic Hmi Comfort Panels 4\\\" Firmware
Siemens Simatic Hmi Comfort Panels 22\\\" Firmware 16
Siemens Simatic Hmi Comfort Panels 22\\\" Firmware
Siemens Simatic Hmi Ktp Mobile Panels Ktp400f Firmware 16
Siemens Simatic Hmi Ktp Mobile Panels Ktp400f Firmware
Siemens Simatic Hmi Ktp Mobile Panels Ktp700 Firmware 16
Siemens Simatic Hmi Ktp Mobile Panels Ktp700 Firmware
7.5
CVSSv3
CVE-2021-27386
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update...
Siemens Simatic Wincc Runtime Advanced
Siemens Simatic Wincc Runtime Advanced 16
Siemens Sinamics Sh150 Firmware
Siemens Sinamics Sm150i Firmware
Siemens Sinamics Gh150 Firmware
Siemens Sinamics Gl150 Firmware
Siemens Sinamics Gm150 Firmware
Siemens Sinamics Sl150 Firmware
Siemens Sinamics Sm120 Firmware
Siemens Sinamics Sm150 Firmware
Siemens Simatic Hmi Comfort Outdoor Panels 7\\\" Firmware
Siemens Simatic Hmi Comfort Outdoor Panels 7\\\" Firmware 16
Siemens Simatic Hmi Comfort Outdoor Panels 15\\\" Firmware
Siemens Simatic Hmi Comfort Outdoor Panels 15\\\" Firmware 16
Siemens Simatic Hmi Comfort Panels 4\\\" Firmware
Siemens Simatic Hmi Comfort Panels 4\\\" Firmware 16
Siemens Simatic Hmi Comfort Panels 22\\\" Firmware
Siemens Simatic Hmi Comfort Panels 22\\\" Firmware 16
Siemens Simatic Hmi Ktp Mobile Panels Ktp400f Firmware
Siemens Simatic Hmi Ktp Mobile Panels Ktp400f Firmware 16
Siemens Simatic Hmi Ktp Mobile Panels Ktp700 Firmware
Siemens Simatic Hmi Ktp Mobile Panels Ktp700 Firmware 16
7.5
CVSSv3
CVE-2021-25660
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update...
Siemens Simatic Hmi Comfort Outdoor Panels 7\\\" Firmware
Siemens Simatic Hmi Comfort Outdoor Panels 7\\\" Firmware 16
Siemens Simatic Hmi Comfort Outdoor Panels 15\\\" Firmware
Siemens Simatic Hmi Comfort Outdoor Panels 15\\\" Firmware 16
Siemens Simatic Hmi Comfort Panels 4\\\" Firmware
Siemens Simatic Hmi Comfort Panels 4\\\" Firmware 16
Siemens Simatic Hmi Comfort Panels 22\\\" Firmware
Siemens Simatic Hmi Comfort Panels 22\\\" Firmware 16
Siemens Simatic Hmi Ktp Mobile Panels Ktp400f Firmware
Siemens Simatic Hmi Ktp Mobile Panels Ktp400f Firmware 16
Siemens Simatic Hmi Ktp Mobile Panels Ktp700 Firmware
Siemens Simatic Hmi Ktp Mobile Panels Ktp700 Firmware 16
Siemens Simatic Hmi Ktp Mobile Panels Ktp700f Firmware
Siemens Simatic Hmi Ktp Mobile Panels Ktp700f Firmware 16
Siemens Simatic Hmi Ktp Mobile Panels Ktp900 Firmware
Siemens Simatic Hmi Ktp Mobile Panels Ktp900 Firmware 16
Siemens Simatic Hmi Ktp Mobile Panels Ktp900f Firmware
Siemens Simatic Hmi Ktp Mobile Panels Ktp900f Firmware 16
Siemens Simatic Wincc Runtime Advanced
Siemens Simatic Wincc Runtime Advanced 16
Siemens Simatic Hmi Comfort Outdoor Panels 7\\\" Firmware 15.1
Siemens Simatic Hmi Comfort Outdoor Panels 15\\\" Firmware 15.1
7.5
CVSSv3
CVE-2021-25661
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update...
Siemens Simatic Wincc Runtime Advanced
Siemens Simatic Wincc Runtime Advanced 16
Siemens Simatic Hmi Comfort Outdoor Panels 7\\\" Firmware
Siemens Simatic Hmi Comfort Outdoor Panels 7\\\" Firmware 16
Siemens Simatic Hmi Comfort Outdoor Panels 15\\\" Firmware
Siemens Simatic Hmi Comfort Outdoor Panels 15\\\" Firmware 16
Siemens Simatic Hmi Comfort Panels 4\\\" Firmware
Siemens Simatic Hmi Comfort Panels 4\\\" Firmware 16
Siemens Simatic Hmi Comfort Panels 22\\\" Firmware
Siemens Simatic Hmi Comfort Panels 22\\\" Firmware 16
Siemens Simatic Hmi Ktp Mobile Panels Ktp400f Firmware
Siemens Simatic Hmi Ktp Mobile Panels Ktp400f Firmware 16
Siemens Simatic Hmi Ktp Mobile Panels Ktp700 Firmware
Siemens Simatic Hmi Ktp Mobile Panels Ktp700 Firmware 16
Siemens Simatic Hmi Ktp Mobile Panels Ktp700f Firmware
Siemens Simatic Hmi Ktp Mobile Panels Ktp700f Firmware 16
Siemens Simatic Hmi Ktp Mobile Panels Ktp900 Firmware
Siemens Simatic Hmi Ktp Mobile Panels Ktp900 Firmware 16
Siemens Simatic Hmi Ktp Mobile Panels Ktp900f Firmware
Siemens Simatic Hmi Ktp Mobile Panels Ktp900f Firmware 16
Siemens Simatic Hmi Comfort Outdoor Panels 7\\\" Firmware 15.1
Siemens Simatic Hmi Comfort Outdoor Panels 15\\\" Firmware 15.1
CVSSv3
CVSSv2
CVSSv3
VMScore
Recommendations:
CVE-2023-7073
CVE-2024-5496
CVE-2024-5495
XPath injection
bypass
CVE-2024-30043
CVE-2024-24919
denial of service
CVE-2024-35468