siemens simatic wincc - vulnerabilities and exploits
(subscribe to this query)
NA
CVE-2014-8552
The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote malicious users to read arbitrary files via crafted packets.
Siemens Simatic Wincc 7.2
Siemens Simatic Pcs7 7.1
Siemens Simatic Pcs 7 7.1
Siemens Simatic Pcs7 8.0
Siemens Simatic Wincc 7.3
Siemens Simatic Pcs7 8.1
Siemens Simatic Tiaportal 13.0
Siemens Simatic Wincc 7.0
6.4
CVSSv3
CVE-2016-7165
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (All versions < V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions < V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIM...
Siemens Security Configuration Tool -
Siemens Simit 9.0
Siemens Sinema Server
Siemens Simatic Net Pc Software
Siemens Simatic Step 7
Siemens Simatic Wincc 7.4
Siemens Simatic Wincc 7.3
Siemens Simatic Pcs 7
Siemens Softnet Security Client
Siemens Telecontrol Basic
Siemens Simatic Step 7 \\(tia Portal\\)
Siemens Simatic Wincc \\(tia Portal\\)
Siemens Simatic Wincc 7.2
Siemens Simatic Wincc 7.0
Siemens Simatic It Production Suite -
Siemens Simatic Winac Rtx F 2010 -
Siemens Simatic Wincc
Siemens Simatic Pcs7 8.2
Siemens Primary Setup Tool -
Siemens Simatic Winac Rtx 2010 -
Siemens Sinema Remote Connect -
Siemens Simatic Wincc \\(tia Portal\\) -
NA
CVE-2013-0675
Buffer overflow in CCEServer (aka the central communications component) in Siemens WinCC prior to 7.2, as used in SIMATIC PCS7 prior to 8.0 SP1 and other products, allows remote malicious users to cause a denial of service via a crafted packet.
Siemens Wincc 7.0
Siemens Simatic Pcs7 7.1
Siemens Wincc 6.0
Siemens Wincc 5.0
Siemens Wincc
Siemens Simatic Pcs7
NA
CVE-2013-0676
Siemens WinCC prior to 7.2, as used in SIMATIC PCS7 prior to 8.0 SP1 and other products, does not properly assign privileges for the database containing WebNavigator credentials, which allows remote authenticated users to obtain sensitive information via a SQL query.
Siemens Wincc 7.0
Siemens Wincc 6.0
Siemens Wincc
Siemens Wincc 5.0
Siemens Simatic Pcs7 7.1
Siemens Simatic Pcs7
NA
CVE-2013-0677
The web server in Siemens WinCC prior to 7.2, as used in SIMATIC PCS7 prior to 8.0 SP1 and other products, allows remote malicious users to obtain sensitive information or cause a denial of service via a crafted project file.
Siemens Wincc 6.0
Siemens Simatic Pcs7
Siemens Simatic Pcs7 7.1
Siemens Wincc 5.0
Siemens Wincc 7.0
Siemens Wincc
NA
CVE-2013-0679
Directory traversal vulnerability in the web server in Siemens WinCC prior to 7.2, as used in SIMATIC PCS7 prior to 8.0 SP1 and other products, allows remote authenticated users to read arbitrary files via vectors involving a query for a pathname.
Siemens Wincc 7.0
Siemens Wincc 6.0
Siemens Wincc
Siemens Wincc 5.0
Siemens Simatic Pcs7 7.1
Siemens Simatic Pcs7
NA
CVE-2013-0674
Buffer overflow in the RegReader ActiveX control in Siemens WinCC prior to 7.2, as used in SIMATIC PCS7 prior to 8.0 SP1 and other products, allows remote malicious users to execute arbitrary code via a long parameter.
Siemens Wincc 6.0
Siemens Wincc 5.0
Siemens Wincc 7.0
Siemens Simatic Pcs7
Siemens Simatic Pcs7 7.1
Siemens Wincc
NA
CVE-2011-4879
miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not...
Siemens Wincc Flexible 2008
Siemens Wincc Flexible 2004
Siemens Wincc Flexible 2005
Siemens Wincc Flexible 2007
Siemens Wincc
Siemens Wincc V11
Siemens Simatic Hmi Panels Tp
Siemens Simatic Hmi Panels Op
Siemens Simatic Hmi Panels Mp
Siemens Simatic Hmi Panels Comfort Panels
Siemens Simatic Hmi Panels Mobile Panels
Siemens Wincc Runtime Advanced V11
Siemens Wincc Flexible Runtime
1 EDB exploit
NA
CVE-2011-4508
The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable a...
Siemens Wincc Flexible 2008
Siemens Wincc Flexible 2004
Siemens Wincc Flexible 2005
Siemens Wincc Flexible 2007
Siemens Wincc
Siemens Wincc V11
Siemens Simatic Hmi Panels Op
Siemens Simatic Hmi Panels Comfort Panels
Siemens Simatic Hmi Panels Tp
Siemens Simatic Hmi Panels Mp
Siemens Simatic Hmi Panels Mobile Panels
Siemens Wincc Runtime Advanced V11
Siemens Wincc Flexible Runtime
NA
CVE-2011-4510
Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and Wi...
Siemens Wincc Flexible 2008
Siemens Wincc Flexible 2005
Siemens Wincc Flexible 2004
Siemens Wincc Flexible 2007
Siemens Wincc
Siemens Wincc V11
Siemens Simatic Hmi Panels Mp
Siemens Simatic Hmi Panels Comfort Panels
Siemens Simatic Hmi Panels Mobile Panels
Siemens Simatic Hmi Panels Op
Siemens Simatic Hmi Panels Tp
Siemens Wincc Runtime Advanced V11
Siemens Wincc Flexible Runtime
CVSSv3
CVSSv2
CVSSv3
VMScore
Recommendations:
NULL pointer dereference
CVE-2023-52689
CVE-2024-23803
client side
CVE-2023-52696
information disclosure
CVE-2024-35843
CVE-2024-27130
CVE-2023-52697
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
« PREV
1
2
3
4
5
6
7
8
NEXT »