schneider-electric vulnerabilities and exploits
(subscribe to this query)
NA
CVE-2023-28004
A CWE-129: Improper validation of an array index vulnerability exists where a specially crafted Ethernet request could result in denial of service or remote code execution.
Schneider-electric Powerlogic Hdpm6000 Firmware
NA
CVE-2023-29411
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow changes to administrative credentials, leading to potential remote code execution without requiring prior authentication on the Java RMI interface.
Schneider-electric Apc Easy Ups Online Monitoring Software
Schneider-electric Easy Ups Online Monitoring Software
NA
CVE-2023-29412
A CWE-78: Improper Handling of Case Sensitivity vulnerability exists that could cause remote code execution when manipulating internal methods through Java RMI interface.
Schneider-electric Apc Easy Ups Online Monitoring Software
Schneider-electric Easy Ups Online Monitoring Software
NA
CVE-2023-29413
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause Denial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor service.
Schneider-electric Apc Easy Ups Online Monitoring Software
Schneider-electric Easy Ups Online Monitoring Software
NA
CVE-2023-25547
A CWE-863: Incorrect Authorization vulnerability exists that could allow remote code execution on upload and install packages when a hacker is using a low privileged user account. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
Schneider-electric Struxureware Data Center Expert
NA
CVE-2023-25548
A CWE-863: Incorrect Authorization vulnerability exists that could allow access to device credentials on specific DCE endpoints not being properly secured when a hacker is using a low privileged user. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
Schneider-electric Struxureware Data Center Expert
NA
CVE-2023-25549
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that allows for remote code execution when using a parameter of the DCE network settings endpoint. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
Schneider-electric Struxureware Data Center Expert
NA
CVE-2023-25550
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that allows remote code execution via the “hostname” parameter when maliciously crafted hostname syntax is entered. Affected products: StruxureWare Data Center Expert (...
Schneider-electric Struxureware Data Center Expert
NA
CVE-2023-25551
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists on a DCE file upload endpoint when tampering with parameters over HTTP. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
Schneider-electric Struxureware Data Center Expert
NA
CVE-2023-25552
A CWE-862: Missing Authorization vulnerability exists that could allow viewing of unauthorized content, changes or deleting of content, or performing unauthorized functions when tampering the Device File Transfer settings on DCE endpoints. Affected products: StruxureWare Data Ce...
Schneider-electric Struxureware Data Center Expert
CVSSv2
CVSSv2
CVSSv3
VMScore
Recommendations:
blind SQL injection
SSRF
buffer overflow
CVE-2023-28952
CVE-2023-41822
CVE-2024-27956
CVE-2023-7028
CVE-2024-34447
CVE-2024-34460