schneider-electric interactive graphical scada system vulnerabilities and exploits
(subscribe to this query)
NA
CVE-2022-24324
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Products: IGSS Data Server - IGSSdataServer.exe (Ver...
Schneider-electric Interactive Graphical Scada System
6.8
CVSSv2
CVE-2020-7555
A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
Schneider-electric Interactive Graphical Scada System
4.6
CVSSv2
CVE-2017-9967
A security misconfiguration vulnerability exists in Schneider Electric's IGSS SCADA Software versions 12 and prior. Security configuration settings such as Address Space Layout Randomization (ASLR) and Data Execution prevention (DEP) were not properly configured resulting in...
Schneider-electric Interactive Graphical Scada System
NA
CVE-2022-32524
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted time reduced data messages. Affected Products: IGSS Data Server - IGSSd...
Schneider-electric Interactive Graphical Scada System
NA
CVE-2022-32526
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted setting value messages. Affected Products: IGSS Data Server - IGSSdataS...
Schneider-electric Interactive Graphical Scada System
NA
CVE-2022-32528
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause access to manipulate and read specific files in the IGSS project report directory, potentially leading to a denial-of-service condition when an attacker sends specific messages. Affecte...
Schneider-electric Interactive Graphical Scada System
NA
CVE-2022-2329
A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Products: IGSS Data Server - IGSSdat...
Schneider-electric Interactive Graphical Scada System
6.8
CVSSv2
CVE-2021-22750
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21041 and prior that could result in loss of data or remote code execution due to missing length checks, when a malicious CGF file is imported to IGSS Definition.
Schneider-electric Interactive Graphical Scada System
NA
CVE-2022-32523
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted online data request messages. Affected Products: IGSS Data Server - IGS...
Schneider-electric Interactive Graphical Scada System
NA
CVE-2022-32525
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm data messages. Affected Products: IGSS Data Server - IGSSdataServ...
Schneider-electric Interactive Graphical Scada System
CVSSv2
CVSSv2
CVSSv3
VMScore
Recommendations:
CVE-2023-52710
arbitrary
CVE-2024-5272
CVE-2024-2961
brute force
remote
CVE-2024-32944
CVE-2024-36241
CVE-2024-5274