schneider-electric vulnerabilities and exploits
(subscribe to this query)
6.1
CVSSv3
CVE-2023-25553
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists on a DCE endpoint through the logging capabilities of the webserver. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
Schneider-electric Struxureware Data Center Expert
7.8
CVSSv3
CVE-2023-25554
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that allows a local privilege escalation on the appliance when a maliciously crafted Operating System command is entered on the device. Affected pr...
Schneider-electric Struxureware Data Center Expert
8.1
CVSSv3
CVE-2023-25555
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow a user that knows the credentials to execute unprivileged shell commands on the appliance over SSH. Affected products: StruxureWar...
Schneider-electric Struxureware Data Center Expert
9.8
CVSSv3
CVE-2023-29411
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow changes to administrative credentials, leading to potential remote code execution without requiring prior authentication on the Java RMI interface.
Schneider-electric Apc Easy Ups Online Monitoring Software
Schneider-electric Easy Ups Online Monitoring Software
9.8
CVSSv3
CVE-2023-29412
A CWE-78: Improper Handling of Case Sensitivity vulnerability exists that could cause remote code execution when manipulating internal methods through Java RMI interface.
Schneider-electric Apc Easy Ups Online Monitoring Software
Schneider-electric Easy Ups Online Monitoring Software
7.5
CVSSv3
CVE-2023-29413
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause Denial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor service.
Schneider-electric Apc Easy Ups Online Monitoring Software
Schneider-electric Easy Ups Online Monitoring Software
6.7
CVSSv3
CVE-2022-34755
A CWE-427 - Uncontrolled Search Path Element vulnerability exists that could allow an attacker with a local privileged account to place a specially crafted file on the target machine, which may give the attacker the ability to execute arbitrary code during the installation proce...
Schneider-electric Easergy Builder Installer
6.1
CVSSv3
CVE-2022-43376
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause code and session manipulation when malicious code is inserted into the browser. Affected Products: NetBotz 4 - 355/450/455/550/570 (V4.7...
Schneider-electric Netbotz 355 Firmware
Schneider-electric Netbotz 450 Firmware
Schneider-electric Netbotz 455 Firmware
Schneider-electric Netbotz 550 Firmware
Schneider-electric Netbotz 570 Firmware
7.5
CVSSv3
CVE-2022-43377
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could cause account takeover when a brute force attack is performed on the account. Affected Products: NetBotz 4 - 355/450/455/550/570 (V4.7.0 and prior)
Schneider-electric Netbotz 355 Firmware
Schneider-electric Netbotz 450 Firmware
Schneider-electric Netbotz 455 Firmware
Schneider-electric Netbotz 550 Firmware
Schneider-electric Netbotz 570 Firmware
8.8
CVSSv3
CVE-2023-25556
A CWE-287: Improper Authentication vulnerability exists that could allow a device to be compromised when a key of less than seven digits is entered and the attacker has access to the KNX installation.
Schneider-electric Merten Instabus Tastermodul 1fach System M Firmware 1.0
Schneider-electric Merten Instabus Tastermodul 2fach System M Firmware 1.0
Schneider-electric Merten Tasterschnittstelle 4fach Plus Firmware 1.0
Schneider-electric Merten Tasterschnittstelle 4fach Plus Firmware 1.2
Schneider-electric Merten Knx Argus 180\\/2\\,20m Up System Firmware 1.0
Schneider-electric Merten Jalousie-\\/schaltaktor Reg-k\\/8x\\/16x\\/10 M. Hb Firmware 1.0
Schneider-electric Merten Knx Uni-dimmaktor Ll Reg-k\\/2x230\\/300 W Firmware 1.0
Schneider-electric Merten Knx Uni-dimmaktor Ll Reg-k\\/2x230\\/300 W Firmware 1.1
Schneider-electric Merten Knx Schaltakt.2x6a Up M.2 Eing. Firmware 0.1
CVSSv3
CVSSv2
CVSSv3
VMScore
Recommendations:
CVE-2023-30310
CVE-2024-21683
CVE-2024-22187
chrome
deserialization
XPath injection
CVE-2024-27842
denial of service
CVE-2024-24851
google
CVE-2024-35400
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
« PREV
1
2
3
4
5
6
7
8
9
10
NEXT »