interactive graphical scada system vulnerabilities and exploits
(subscribe to this query)
5
CVSSv2
CVE-2022-24314
A CWE-125: Out-of-bounds Read vulnerability exists that could cause memory leaks potentially resulting in denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
Schneider-electric Interactive Graphical Scada System Data Server
5
CVSSv2
CVE-2022-24315
A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
Schneider-electric Interactive Graphical Scada System Data Server
5
CVSSv2
CVE-2022-24316
A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
Schneider-electric Interactive Graphical Scada System Data Server
5
CVSSv2
CVE-2022-24317
A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
Schneider-electric Interactive Graphical Scada System Data Server
7.5
CVSSv2
CVE-2021-22802
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution due to missing length check on user supplied data, when a constructed message is received on the network. Affected Product: Interactive Graphical SCADA System Dat...
Schneider-electric Interactive Graphical Scada System Data Collector
7.5
CVSSv2
CVE-2021-22803
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could lead to remote code execution through a number of paths, when an attacker, writes arbitrary files to folders in context of the DC module, by sending constructed messages on the network. Aff...
Schneider-electric Interactive Graphical Scada System Data Collector
5
CVSSv2
CVE-2021-22805
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc...
Schneider-electric Interactive Graphical Scada System Data Collector
10
CVSSv2
CVE-2011-1566
Directory traversal vulnerability in dc.exe 9.00.00.11059 and previous versions in 7-Technologies Interactive Graphical SCADA System (IGSS) allows remote malicious users to execute arbitrary programs via ..\ (dot dot backslash) sequences in opcodes (1) 0xa and (2) 0x17 to TCP por...
7t Igss
2 EDB exploits
5
CVSSv2
CVE-2011-4050
Buffer overflow in 7-Technologies (7T) Interactive Graphical SCADA System (IGSS) 9.0.0.11200 allows remote malicious users to cause a denial of service via a crafted packet to TCP port 12401.
7t Igss 9.0.0.11200
9.3
CVSSv2
CVE-2011-4053
Untrusted search path vulnerability in 7-Technologies (7T) Interactive Graphical SCADA System (IGSS) prior to 9.0.0.11291 allows local users to gain privileges via a Trojan horse DLL in the current working directory.
7t Igss 9.0.0.11129
7t Igss 8
7t Igss 6
7t Igss 2.0
7t Igss 5.1
7t Igss 5.0
7t Igss 4.1
7t Igss 3.0
7t Igss 9
7t Igss 7
7t Igss
CVSSv2
CVSSv2
CVSSv3
VMScore
Recommendations:
CVE-2022-48700
CVE-2022-48689
CVE-2024-27956
CVE-2023-6363
SQL
NULL pointer dereference
CVE-2023-41830
CVE-2015-2051
arbitrary
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
« PREV
1
2
3
4
5
6
7
NEXT »