Vulmon
Recent Vulnerabilities
Research Posts
Trends
Blog
About
Contact
Vulmon Alerts
By Relevance
By Risk Score
By Publish Date
rack vulnerabilities and exploits
(subscribe to this query)
7.5
CVSSv3
CVE-2021-23236
Requests may be used to interrupt the normal operation of the device. When exploited, Fresenius Kabi Agilia Link+ version 3.0 must be rebooted via a hard reset triggered by pressing a button on the rack system.
Fresenius-kabi Agilia Partner Maintenance Software
Fresenius-kabi Vigilant Centerium 1.0
Fresenius-kabi Vigilant Insight 1.0
Fresenius-kabi Vigilant Mastermed 1.0
Fresenius-kabi Agilia Connect Firmware
Fresenius-kabi Link\\+ Agilia Firmware
Fresenius-kabi Link\\+ Agilia Firmware 3.0
6
CVSSv3
CVE-2022-22558
Dell PowerEdge Server BIOS and Dell Precision Workstation 7910 and 7920 Rack BIOS contain an Improper SMM communication buffer verification vulnerability. A Local High Privileged attacker could potentially exploit this vulnerability leading to arbitrary writes or denial of servic...
Dell R6415 Firmware
Dell R7415 Firmware
Dell R7425 Firmware
Dell R730 Firmware
Dell R730xd Firmware
Dell R630 Firmware
Dell C4130 Firmware
Dell M630 Firmware
Dell M630p Firmware
Dell Fc630 Firmware
Dell Fc430 Firmware
Dell M830 Firmware
Dell M830p Firmware
Dell Fc830 Firmware
Dell T630 Firmware
Dell R530 Firmware
Dell R430 Firmware
Dell T430 Firmware
Dell R830 Firmware
Dell C6320 Firmware
6.6
CVSSv3
CVE-2016-6898
XML external entity (XXE) vulnerability in the Hyper Management Module (HMM) in Huawei E9000 rack servers with software before V100R001C00SPC296 allows remote authenticated users to read arbitrary files or cause a denial of service (web service outage) via a crafted XML document.
Huawei E9000 Chassis
7.5
CVSSv3
CVE-2019-5599
In FreeBSD 12.0-STABLE before r349197 and 12.0-RELEASE prior to 12.0-RELEASE-p6, a bug in the non-default RACK TCP stack can allow an malicious user to cause several linked lists to grow unbounded and cause an expensive list traversal on every packet being processed, leading to r...
Freebsd Freebsd 12.0
1 Article
6.7
CVSSv3
CVE-2021-21557
Dell PowerEdge Server BIOS and select Dell Precision Rack BIOS contain an out-of-bounds array access vulnerability. A local malicious user with high privileges may potentially exploit this vulnerability, leading to a denial of service, arbitrary code execution, or information dis...
Dell Poweredge R640 Firmware
Dell Poweredge R740 Firmware
Dell Poweredge R740xd Firmware
Dell Poweredge R940 Firmware
Dell Poweredge R540 Firmware
Dell Poweredge R440 Firmware
Dell Poweredge T440 Firmware
Dell Poweredge Xr2 Firmware
Dell Poweredge R740xd2 Firmware
Dell Poweredge R840 Firmware
Dell Poweredge R940xa Firmware
Dell Poweredge T640 Firmware
Dell Poweredge C6420 Firmware
Dell Poweredge Fc640 Firmware
Dell Poweredge M640 Firmware
Dell Poweredge M640p Firmware
Dell Poweredge Mx740c Firmware
Dell Poweredge Mx840c Firmware
Dell Poweredge C4140 Firmware
Dell Poweredge T140 Firmware
Dell Poweredge T340 Firmware
Dell Poweredge R240 Firmware
NA
CVE-2013-1190
The C-Series Rack Server component 1.4 in Cisco Unified Computing System (UCS) does not properly restrict inbound access to ports, which allows remote malicious users to cause a denial of service (Integrated Management Controller reboot or hang) via crafted packets, as demonstrat...
Cisco Unified Computing System -
7
CVSSv3
CVE-2016-8221
Privilege Escalation in Lenovo XClarity Administrator earlier than 1.2.0, if LXCA is used to manage rack switches or chassis with embedded input/output modules (IOMs), certain log files viewable by authenticated users may contain passwords for internal administrative LXCA account...
Lenovo Xclarity Administrator
9.8
CVSSv3
CVE-2021-38412
Properly formatted POST requests to multiple resources on the HTTP and HTTPS web servers of the Digi PortServer TS 16 Rack device do not require authentication or authentication tokens. This vulnerability could allow an malicious user to enable the SNMP service and manipulate the...
Digi Portserver Ts 16 Firmware 82000684
Digi Portserver Ts 16 Firmware 82000685
5.3
CVSSv3
CVE-2021-22815
A CWE-200: Information Exposure vulnerability exists which could cause the troubleshooting archive to be accessed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630...
Schneider-electric Network Management Card 2 Firmware
Schneider-electric Network Management Card 3 Firmware
NA
CVE-2009-1797
Multiple cross-site request forgery (CSRF) vulnerabilities on the Network Management Card (NMC) on American Power Conversion (APC) Switched Rack PDU (aka Rack Mount Power Distribution) devices and other devices allow remote malicious users to hijack the authentication of (1) admi...
Apc Network Management Card
Apc Switched Rack Pdu
CVSSv3
CVSSv2
CVSSv3
VMScore
Recommendations:
CVE-2024-27322
cross-site request forgery
unauthorized
CVE-2024-33925
reflected XSS
CVE-2023-51580
CVE-2023-51579
CVE-2015-2051
CVE-2023-51609
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
« PREV
1
2
3
4
5
6
7
8
9
10
NEXT »