Vulmon
Recent Vulnerabilities
Research Posts
Trends
Blog
About
Contact
Vulmon Alerts
By Relevance
By Risk Score
By Publish Date
schneider-electric interactive graphical scada system vulnerabilities and exploits
(subscribe to this query)
9.1
CVSSv3
CVE-2021-22805
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc...
Schneider-electric Interactive Graphical Scada System Data Collector
7.5
CVSSv3
CVE-2021-22824
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network. Affected Product: Interactive Graphical SCADA System Data Colle...
Schneider-electric Interactive Graphical Scada System Data Collector
9.8
CVSSv3
CVE-2021-22802
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution due to missing length check on user supplied data, when a constructed message is received on the network. Affected Product: Interactive Graphical SCADA System Dat...
Schneider-electric Interactive Graphical Scada System Data Collector
9.8
CVSSv3
CVE-2021-22803
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could lead to remote code execution through a number of paths, when an attacker, writes arbitrary files to folders in context of the DC module, by sending constructed messages on the network. Aff...
Schneider-electric Interactive Graphical Scada System Data Collector
7.5
CVSSv3
CVE-2021-22804
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause disclosure of arbitrary files being read in the context of the user running IGSS, due to missing validation of user supplied data in network messages. Affected Product: Int...
Schneider-electric Interactive Graphical Scada System Data Collector
9.1
CVSSv3
CVE-2021-22823
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc...
Schneider-electric Interactive Graphical Scada System Data Collector
7.5
CVSSv3
CVE-2022-24314
A CWE-125: Out-of-bounds Read vulnerability exists that could cause memory leaks potentially resulting in denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
Schneider-electric Interactive Graphical Scada System Data Server
CVSSv3
CVSSv2
CVSSv3
VMScore
Recommendations:
CVE-2024-4651
CVE-2024-34255
elevation of privilege
CVE-2024-25529
CVE-2024-4671
NULL pointer dereference
CVE-2024-25527
template injection
CVE-2008-0166
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
« PREV
1
2
3
4
5
6