Vulmon
Recent Vulnerabilities
Research Posts
Trends
Blog
About
Contact
Vulmon Alerts
By Relevance
By Risk Score
By Publish Date
juniper junos 19.3 vulnerabilities and exploits
(subscribe to this query)
5.8
CVSSv2
CVE-2020-1637
A vulnerability in Juniper Networks SRX Series device configured as a Junos OS Enforcer device may allow a user to access network resources that are not permitted by a UAC policy. This issue might occur when the IP address range configured in the Infranet Controller (IC) is confi...
Juniper Junos 12.3x48
Juniper Junos 15.1x49
Juniper Junos 17.3
Juniper Junos 17.4
Juniper Junos 18.1
Juniper Junos 18.2
Juniper Junos 18.3
Juniper Junos 18.4
Juniper Junos 19.1
Juniper Junos 19.2
Juniper Junos 19.3
Juniper Junos 19.4
7.2
CVSSv2
CVE-2021-0218
A command injection vulnerability in the license-check daemon of Juniper Networks Junos OS that may allow a locally authenticated attacker with low privileges to execute commands with root privilege. license-check is a daemon used to manage licenses in Junos OS. To update license...
Juniper Junos 18.2
Juniper Junos 17.3
Juniper Junos 17.4
Juniper Junos 18.1
Juniper Junos 18.3
Juniper Junos 18.4
Juniper Junos 19.1
Juniper Junos 19.2
Juniper Junos 19.3
Juniper Junos 19.4
Juniper Junos 20.1
Juniper Junos 20.2
5
CVSSv2
CVE-2022-22185
A vulnerability in Juniper Networks Junos OS on SRX Series, allows a network-based unauthenticated malicious user to cause a Denial of Service (DoS) by sending a specific fragmented packet to the device, resulting in a flowd process crash, which is responsible for packet forwardi...
Juniper Junos 18.3
Juniper Junos 18.4
Juniper Junos 19.1
Juniper Junos 19.2
Juniper Junos 19.3
Juniper Junos 19.4
Juniper Junos 20.1
Juniper Junos 20.2
Juniper Junos 20.3
Juniper Junos 20.4
Juniper Junos 21.1
Juniper Junos 21.2
4.3
CVSSv2
CVE-2021-0205
When the "Intrusion Detection Service" (IDS) feature is configured on Juniper Networks MX series with a dynamic firewall filter using IPv6 source or destination prefix, it may incorrectly match the prefix as /32, causing the filter to block unexpected traffic. This issu...
Juniper Junos 17.3
Juniper Junos 17.4
Juniper Junos 18.1
Juniper Junos 18.2
Juniper Junos 18.3
Juniper Junos 18.4
Juniper Junos 19.1
Juniper Junos 19.2
Juniper Junos 19.3
Juniper Junos 19.4
Juniper Junos 20.1
Juniper Junos 20.2
2.1
CVSSv2
CVE-2021-0238
When a MX Series is configured as a Broadband Network Gateway (BNG) based on Layer 2 Tunneling Protocol (L2TP), executing certain CLI command may cause the system to run out of disk space, excessive disk usage may cause other complications. An administrator can use the following ...
Juniper Junos 17.3
Juniper Junos 18.1
Juniper Junos 18.2
Juniper Junos 18.3
Juniper Junos 19.1
Juniper Junos 19.2
Juniper Junos 19.3
Juniper Junos 19.4
Juniper Junos 20.1
Juniper Junos 20.2
Juniper Junos 20.3
Juniper Junos 20.4
5
CVSSv2
CVE-2021-0280
Due to an Improper Initialization vulnerability in Juniper Networks Junos OS on PTX platforms and QFX10K Series with Paradise (PE) chipset-based line cards, ddos-protection configuration changes made from the CLI will not take effect as expected beyond the default DDoS (Distribut...
Juniper Junos 17.4
Juniper Junos 18.2
Juniper Junos 18.3
Juniper Junos 18.4
Juniper Junos 19.1
Juniper Junos 19.2
Juniper Junos 19.3
Juniper Junos 19.4
Juniper Junos 20.1
Juniper Junos 20.2
Juniper Junos 20.3
Juniper Junos 20.4
NA
CVE-2023-28972
An Improper Link Resolution Before File Access vulnerability in console port access of Juniper Networks Junos OS on NFX Series allows an malicious user to bypass console access controls. When "set system ports console insecure" is enabled, root login is disallowed for J...
Juniper Junos 19.2
Juniper Junos 19.3
Juniper Junos 19.4
Juniper Junos 20.2
Juniper Junos 20.4
Juniper Junos 21.1
Juniper Junos 21.2
Juniper Junos 21.3
Juniper Junos 21.4
Juniper Junos 22.1
Juniper Junos 22.2
Juniper Junos 22.3
7.8
CVSSv2
CVE-2021-31368
An Uncontrolled Resource Consumption vulnerability in the kernel of Juniper Networks JUNOS OS allows an unauthenticated network based malicious user to cause 100% CPU load and the device to become unresponsive by sending a flood of traffic to the out-of-band management ethernet p...
Juniper Junos
Juniper Junos 18.1
Juniper Junos 18.2
Juniper Junos 18.3
Juniper Junos 18.4
Juniper Junos 19.1
Juniper Junos 19.2
Juniper Junos 19.3
Juniper Junos 19.4
Juniper Junos 20.1
Juniper Junos 20.2
Juniper Junos 20.3
Juniper Junos 20.4
4.3
CVSSv2
CVE-2021-31369
On MX Series platforms with MS-MPC/MS-MIC, an Allocation of Resources Without Limits or Throttling vulnerability in Juniper Networks Junos OS allows an unauthenticated network malicious user to cause a partial Denial of Service (DoS) with a high rate of specific traffic. If a Cla...
Juniper Junos
Juniper Junos 17.4
Juniper Junos 18.3
Juniper Junos 18.4
Juniper Junos 19.1
Juniper Junos 19.2
Juniper Junos 19.3
Juniper Junos 19.4
Juniper Junos 20.1
Juniper Junos 20.2
Juniper Junos 20.3
Juniper Junos 20.4
Juniper Junos 21.1
5
CVSSv2
CVE-2021-31371
Juniper Networks Junos OS uses the 128.0.0.0/2 subnet for internal communications between the RE and PFEs. It exists that packets utilizing these IP addresses may egress an QFX5000 Series switch, leaking configuration information such as heartbeats, kernel versions, etc. out to t...
Juniper Junos 17.3
Juniper Junos 18.1
Juniper Junos 18.3
Juniper Junos 19.1
Juniper Junos 19.2
Juniper Junos 19.3
Juniper Junos 19.4
Juniper Junos 20.1
Juniper Junos
Juniper Junos 20.2
Juniper Junos 20.3
Juniper Junos 20.4
Juniper Junos 21.1
CVSSv2
CVSSv2
CVSSv3
VMScore
Recommendations:
CVE-2024-3201
CVE-2024-4779
CVE-2024-35090
CVE-2024-5084
hard-coded
CVE-2024-4985
HTML injection
CVE-2024-33655
local file inclusion
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
« PREV
3
4
5
6
7
8
9
10
NEXT »