Vulmon
Recent Vulnerabilities
Research Posts
Trends
Blog
About
Contact
Vulmon Alerts
By Relevance
By Risk Score
By Publish Date
nexus vulnerabilities and exploits
(subscribe to this query)
7.8
CVSSv2
CVE-2021-37166
A buffer overflow issue leading to denial of service exists in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When HMI3 starts up, it binds a local service to a TCP port on all interfaces of the devic...
Swisslog-healthcare Hmi-3 Control Panel Firmware
10
CVSSv2
CVE-2021-37167
An insecure permissions issue exists in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. A user logged in using the default credentials can gain root access to the device, which provides permissions for...
Swisslog-healthcare Hmi-3 Control Panel Firmware
7.5
CVSSv2
CVE-2021-37161
A buffer overflow issue exists in the HMI3 Control Panel contained within the Swisslog Healthcare Nexus Panel, operated by released versions of software before Nexus Software 7.2.5.7. A buffer overflow allows an malicious user to overwrite an internal queue data structure and can...
Swisslog-healthcare Hmi-3 Control Panel Firmware
7.5
CVSSv2
CVE-2021-37163
An insecure permissions issue exists in HMI3 Control Panel in Swisslog Healthcare Nexus operated by released versions of software before Nexus Software 7.2.5.7. The device has two user accounts with passwords that are hardcoded.
Swisslog-healthcare Hmi-3 Control Panel Firmware
7.5
CVSSv2
CVE-2021-37164
A buffer overflow issue exists in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. In the tcpTxThread function, the received data is copied to a stack buffer. An off-by-3 condition can occur, resulting ...
Swisslog-healthcare Hmi-3 Control Panel Firmware
7.5
CVSSv2
CVE-2021-37165
A buffer overflow issue exists in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When a message is sent to the HMI TCP socket, it is forwarded to the hmiProcessMsg function through the pendingQ, and m...
Swisslog-healthcare Hmi-3 Control Panel Firmware
4
CVSSv2
CVE-2021-34553
Sonatype Nexus Repository Manager 3.x prior to 3.31.0 allows a remote authenticated malicious user to get a list of blob files and read the content of a blob file (via a GET request) without having been granted access.
Sonatype Nexus Repository Manager
4.3
CVSSv2
CVE-2021-29159
A cross-site scripting (XSS) vulnerability has been discovered in Nexus Repository Manager 3.x prior to 3.30.1. An attacker with a local account can create entities with crafted properties that, when viewed by an administrator, can execute arbitrary JavaScript in the context of t...
5
CVSSv2
CVE-2021-30635
Sonatype Nexus Repository Manager 3.x prior to 3.30.1 allows a remote malicious user to get a list of files and directories that exist in a UI-related folder via directory traversal (no customer-specific data is exposed).
4
CVSSv2
CVE-2021-29158
Sonatype Nexus Repository Manager 3 Pro up to and including 3.30.0 has Incorrect Access Control.
CVSSv2
CVSSv2
CVSSv3
VMScore
Recommendations:
authentication bypass
CVE-2024-30043
camera
CVE-2023-40404
CVE-2024-2793
client side
CVE-2024-4469
CVE-2024-3565
CVE-2024-29825
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
« PREV
3
4
5
6
7
8
9
10
NEXT »