siemens wincc vulnerabilities and exploits
(subscribe to this query)
5.8
CVSSv2
CVE-2016-9160
A vulnerability in SIEMENS SIMATIC WinCC (All versions < SIMATIC WinCC V7.2) and SIEMENS SIMATIC PCS 7 (All versions < SIMATIC PCS 7 V8.0 SP1) could allow a remote malicious user to crash an ActiveX component or leak parts of the application memory if a user is tricked into...
Siemens Simatic Wincc
Siemens Simatic Pcs 7
4.3
CVSSv2
CVE-2013-0667
Cross-site scripting (XSS) vulnerability in the HMI web application in Siemens WinCC (TIA Portal) 11 allows remote malicious users to inject arbitrary web script or HTML via a crafted URL.
Siemens Wincc Tia Portal 11.0
4.3
CVSSv2
CVE-2013-0668
Multiple cross-site scripting (XSS) vulnerabilities in the HMI web application in Siemens WinCC (TIA Portal) 11 allow remote malicious users to inject arbitrary web script or HTML via a crafted URL.
Siemens Wincc Tia Portal 11.0
4
CVSSv2
CVE-2013-0669
The HMI web application in Siemens WinCC (TIA Portal) 11 allows remote authenticated users to cause a denial of service (daemon crash) via a crafted HTTP request.
Siemens Wincc Tia Portal 11.0
4.3
CVSSv2
CVE-2013-0670
CRLF injection vulnerability in the HMI web application in Siemens WinCC (TIA Portal) 11 allows remote malicious users to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via a crafted URL.
Siemens Wincc Tia Portal 11.0
4
CVSSv2
CVE-2013-0671
Directory traversal vulnerability in Siemens WinCC (TIA Portal) 11 allows remote authenticated users to read HMI web-application source code and user-defined scripts via a crafted URL.
Siemens Wincc Tia Portal 11.0
3.5
CVSSv2
CVE-2013-0672
Cross-site scripting (XSS) vulnerability in the HMI web application in Siemens WinCC (TIA Portal) 11 allows remote authenticated users to inject arbitrary web script or HTML via unspecified data.
Siemens Wincc Tia Portal 11.0
4.6
CVSSv2
CVE-2011-4515
Siemens WinCC (TIA Portal) 11 uses a reversible algorithm for storing HMI web-application passwords in world-readable and world-writable files, which allows local users to obtain sensitive information by leveraging (1) physical access or (2) Sm@rt Server access.
Siemens Wincc Tia Portal 11.0
6.4
CVSSv2
CVE-2018-13799
A vulnerability has been identified in SIMATIC WinCC OA V3.14 and prior (All versions < V3.14-P021). Improper access control to a data point of the affected product could allow an unauthenticated remote user to escalate its privileges in the context of SIMATIC WinCC OA V3.14. ...
Siemens Simatic Wincc Open Architecture
5.8
CVSSv2
CVE-2017-6870
A vulnerability exists in Siemens SIMATIC WinCC Sm@rtClient for Android (All versions before V1.0.2.2). The existing TLS protocol implementation could allow an malicious user to read and modify data within a TLS session while performing a Man-in-the-Middle (MitM) attack.
Siemens Simatic Wincc Sm\\@rtclient
CVSSv2
CVSSv2
CVSSv3
VMScore
Recommendations:
camera
bypass
CVE-2024-3592
CVE-2024-37383
CVE-2024-24919
CVE-2024-27822
CVE-2024-36788
CVE-2024-36789
man-in-the-middle
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
« PREV
4
5
6
7
8
9
10
NEXT »