641
VMScore
CVE-2020-36547
A vulnerability was found in GE Voluson S8. It has been rated as critical. This issue affects the Service Browser which itroduces hard-coded credentials. Attacking locally is a requirement. It is recommended to change the configuration settings.
Ge Voluson S8 Firmware -
641
VMScore
CVE-2020-36548
A vulnerability classified as problematic has been found in GE Voluson S8. Affected is the file /uscgi-bin/users.cgi of the Service Browser. The manipulation leads to improper authentication and elevated access possibilities. It is possible to launch the attack on the local host.
Ge Voluson S8 Firmware -
641
VMScore
CVE-2020-36549
A vulnerability classified as critical was found in GE Voluson S8. Affected is the underlying Windows XP operating system. Missing patches might introduce an excessive attack surface. Access to the local network is required for this attack to succeed.
Ge Voluson S8 Firmware -
187
VMScore
CVE-2019-18243
HMI/SCADA iFIX (Versions 6.1 and prior) allows a local authenticated user to modify system-wide iFIX configurations through the registry. This may allow privilege escalation.
Ge Ifix
187
VMScore
CVE-2019-18255
HMI/SCADA iFIX (Versions 6.1 and prior) allows a local authenticated user to modify system-wide iFIX configurations through section objects. This may allow privilege escalation.
Ge Ifix
668
VMScore
CVE-2022-21798
The affected product is vulnerable due to cleartext transmission of credentials seen in the CIMPLICITY network, which can be easily spoofed and used to log in to make operational changes to the system.
Ge Cimplicity
445
VMScore
CVE-2021-44477
GE Gas Power ToolBoxST Version v04.07.05C suffers from an XML external entity (XXE) vulnerability using the DTD parameter entities technique that could result in disclosure and retrieval of arbitrary data on the affected node via an out-of-band (OOB) attack. The vulnerability is ...
Ge Toolboxst
NA
CVE-2022-43977
An issue exists on GE Grid Solutions MS3000 devices prior to 3.7.6.25p0_3.2.2.17p0_4.7p0. The debug port accessible via TCP (a qconn service) lacks access control.
Ge Ms 3000 Firmware
NA
CVE-2022-2002
GE CIMPICITY versions 2022 and prior is vulnerable when data from faulting address controls code flow starting at gmmiObj!CGmmiOptionContainer, which could allow an malicious user to execute arbitrary code.
Ge Cimplicity
570
VMScore
CVE-2012-0232
Directory traversal vulnerability in rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6, 3.0, 3.0 SP1, and 3.5 allows remote malicious users to modify the configuration via crafted strings.
Ge Intelligent Platforms Proficy Real-time Information Portal 2.6
Ge Intelligent Platforms Proficy Real-time Information Portal 3.0
Ge Intelligent Platforms Proficy Real-time Information Portal 3.5
VMScore
CVSSv2
CVSSv3
VMScore
Recommendations:
CVE-2023-40673
CVE-2024-36674
CVE-2024-27348
unspecified
CVE-2024-24919
CVE-2024-4870
malicious code
CVE-2024-2019
hard-coded
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
« PREV
4
5
6
7
8
9
10
NEXT »