4.5
CVSSv3
CVE-2020-12023
Philips IntelliBridge Enterprise (IBE), Versions B.12 and prior, IntelliBridge Enterprise system integration with SureSigns (VS4), EarlyVue (VS30) and IntelliVue Guardian (IGS). Unencrypted user credentials received in the IntelliBridge Enterprise (IBE) are logged within the tran...
Philips Intellibridge Enterprise
7.1
CVSSv3
CVE-2020-16247
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource.
Philips Clinical Collaboration Platform
4.4
CVSSv3
CVE-2019-10968
Philips Holter 2010 Plus, all versions. A vulnerability has been identified that may allow system options that were not purchased to be enabled.
Philips Zymed Holter 2010
9.8
CVSSv3
CVE-2015-2882
Philips In.Sight B120/37 has a password of b120root for the backdoor root account, a password of /ADMIN/ for the backdoor admin account, a password of merlin for the backdoor mg3500 account, a password of M100-4674448 for the backdoor user account, and a password of M100-4674448 ...
Philips In.sight B120\\\\37 -
5.4
CVSSv3
CVE-2015-2883
Philips In.Sight B120/37 has XSS, related to the Weaved cloud web service, as demonstrated by the name parameter to deviceSettings.php or shareDevice.php.
Philips In.sight B120\\\\37 -
7.5
CVSSv3
CVE-2015-2884
Philips In.Sight B120/37 allows remote malicious users to obtain sensitive information via a direct request, related to yoics.net URLs, stream.m3u8 URIs, and cam_service_enable.cgi.
Philips In.sight B120\\\\37 -
4.3
CVSSv3
CVE-2020-14506
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The product receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.
Philips Clinical Collaboration Platform
3.5
CVSSv3
CVE-2020-14525
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output used as a webpage that is served to other users.
Philips Clinical Collaboration Platform
6.3
CVSSv3
CVE-2020-16198
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. When an attacker claims to have a given identity, the software does not prove or insufficiently proves the claim is correct.
Philips Clinical Collaboration Platform
6.5
CVSSv3
CVE-2020-16200
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The software does not properly control the allocation and maintenance of a limited resource, thereby enabling an malicious user to influence the amount of resources consumed, eventually leading to the exhaustion ...
Philips Clinical Collaboration Platform
CVSSv3
CVSSv2
CVSSv3
VMScore
Recommendations:
CVE-2024-5248
CVE-2024-3110
CVE-2024-5552
CVE-2024-29415
HTML injection
CVE-2024-3095
TCP
type confusion
CVE-2024-1800
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
« PREV
4
5
6
7
8
9
10
NEXT »