Vulmon
Recent Vulnerabilities
Research Posts
Trends
Blog
About
Contact
Vulmon Alerts
By Relevance
By Risk Score
By Publish Date
philips vulnerabilities and exploits
(subscribe to this query)
409
VMScore
CVE-2018-19001
Philips HealthSuite Health Android App, all versions. The software uses simple encryption that is not strong enough for the level of protection required.
Philips Healthsuite Health
516
VMScore
CVE-2020-16198
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. When an attacker claims to have a given identity, the software does not prove or insufficiently proves the claim is correct.
Philips Clinical Collaboration Platform
294
VMScore
CVE-2018-8842
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. The Philips e-Alert communication channel is not encrypted which could...
Philips E-alert Firmware
605
VMScore
CVE-2018-8844
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request.
Philips E-alert Firmware
383
VMScore
CVE-2018-8846
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is then served to other users.
Philips E-alert Firmware
668
VMScore
CVE-2018-8850
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not validate input properly, allowing an malicious user to craft the input in a form that is not expected by the rest of the application. This would lead to parts of the unit receiving unintended...
Philips E-alert Firmware
605
VMScore
CVE-2018-8852
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. When authenticating a user or otherwise establishing a new user session, the software gives an attacker the opportunity to steal authenticated sessions without invalidating any existing session identifier.
Philips E-alert Firmware
383
VMScore
CVE-2020-14506
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The product receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.
Philips Clinical Collaboration Platform
890
VMScore
CVE-2015-2882
Philips In.Sight B120/37 has a password of b120root for the backdoor root account, a password of /ADMIN/ for the backdoor admin account, a password of merlin for the backdoor mg3500 account, a password of M100-4674448 for the backdoor user account, and a password of M100-4674448 ...
Philips In.sight B120\\\\37 -
383
VMScore
CVE-2021-32966
Philips Interoperability Solution XDS versions 2.5 up to and including 3.11 and 2018-1 through 2021-1 are vulnerable to clear text transmission of sensitive information when configured to use LDAP via TLS and where the domain controller returns LDAP referrals, which may allow an ...
Philips Interoperability Solution Xds
VMScore
CVSSv2
CVSSv3
VMScore
Recommendations:
inject
CVE-2024-34001
CVE-2024-37018
LFI
CVE-2024-1275
CVE-2024-1086
CSRF
CVE-2024-31030
CVE-2024-24919