codesys runtime system toolkit vulnerabilities and exploits
(subscribe to this query)
668
VMScore
CVE-2019-9010
An issue exists in 3S-Smart CODESYS V3 products. The CODESYS Gateway does not correctly verify the ownership of a communication channel. All variants of the following CODESYS V3 products in all versions prior to v3.5.14.20 that contain the CmpGateway component are affected, regar...
Codesys Control For Beaglebone Sl
Codesys Control For Empc-a\\/imx6 Sl
Codesys Control For Iot2000 Sl
Codesys Control For Linux Sl
Codesys Control For Pfc100 Sl
Codesys Control For Pfc200 Sl
Codesys Control For Raspberry Pi Sl
Codesys Control Runtime Toolkit
Codesys Development System
Codesys Gateway
694
VMScore
CVE-2019-9012
An issue exists in 3S-Smart CODESYS V3 products. A crafted communication request may cause uncontrolled memory allocations in the affected CODESYS products and may result in a denial-of-service condition. All variants of the following CODESYS V3 products in all versions prior to ...
Codesys Control For Beaglebone Sl
Codesys Control For Empc-a\\/imx6 Sl
Codesys Control For Iot2000 Sl
Codesys Control For Linux Sl
Codesys Control For Pfc100 Sl
Codesys Control For Pfc200 Sl
Codesys Control For Raspberry Pi Sl
Codesys Control Runtime Toolkit
Codesys Development System
Codesys Gateway
312
VMScore
CVE-2022-22513
An authenticated remote attacker can cause a null pointer dereference in the CmpSettings component of the affected CODESYS products which leads to a crash.
Codesys Control For Beaglebone Sl
Codesys Control For Beckhoff Cx9020
Codesys Control For Empc-a\\/imx6 Sl
Codesys Control For Iot2000 Sl
Codesys Control For Linux Sl
Codesys Control For Pfc100 Sl
Codesys Control For Pfc200 Sl
Codesys Control For Plcnext Sl
Codesys Control For Raspberry Pi Sl
Codesys Control For Wago Touch Panels 600 Sl
Codesys Control Rte Sl
Codesys Control Rte Sl \\(for Beckhoff Cx\\)
Codesys Control Runtime System Toolkit
Codesys Control Win Sl
Codesys Development System
Codesys Edge Gateway
Codesys Embedded Target Visu Toolkit
Codesys Gateway
Codesys Hmi Sl
Codesys Remote Target Visu Toolkit
437
VMScore
CVE-2022-22514
An authenticated, remote attacker can gain access to a dereferenced pointer contained in a request. The accesses can subsequently lead to local overwriting of memory in the CmpTraceMgr, whereby the attacker can neither gain the values read internally nor control the values to be ...
Codesys Control For Beaglebone Sl
Codesys Control For Beckhoff Cx9020
Codesys Control For Empc-a\\/imx6 Sl
Codesys Control For Iot2000 Sl
Codesys Control For Linux Sl
Codesys Control For Pfc100 Sl
Codesys Control For Pfc200 Sl
Codesys Control For Plcnext Sl
Codesys Control For Raspberry Pi Sl
Codesys Control For Wago Touch Panels 600 Sl
Codesys Control Rte Sl
Codesys Control Rte Sl \\(for Beckhoff Cx\\)
Codesys Control Runtime System Toolkit
Codesys Control Win Sl
Codesys Development System
Codesys Edge Gateway
Codesys Embedded Target Visu Toolkit
Codesys Gateway
Codesys Hmi Sl
Codesys Remote Target Visu Toolkit
446
VMScore
CVE-2022-22517
An unauthenticated, remote attacker can disrupt existing communication channels between CODESYS products by guessing a valid channel ID and injecting packets. This results in the communication channel to be closed.
Codesys Control For Beaglebone Sl
Codesys Control For Beckhoff Cx9020
Codesys Control For Empc-a\\/imx6 Sl
Codesys Control For Iot2000 Sl
Codesys Control For Linux Sl
Codesys Control For Pfc100 Sl
Codesys Control For Pfc200 Sl
Codesys Control For Plcnext Sl
Codesys Control For Raspberry Pi Sl
Codesys Control For Wago Touch Panels 600 Sl
Codesys Control Rte Sl
Codesys Control Rte Sl \\(for Beckhoff Cx\\)
Codesys Control Runtime System Toolkit
Codesys Control Win Sl
Codesys Development System
Codesys Edge Gateway
Codesys Embedded Target Visu Toolkit
Codesys Gateway
Codesys Hmi Sl
Codesys Remote Target Visu Toolkit
516
VMScore
CVE-2019-9013
An issue exists in 3S-Smart CODESYS V3 products. The application may utilize non-TLS based encryption, which results in user credentials being insufficiently protected during transport. All variants of the following CODESYS V3 products in all versions containing the CmpUserMgr co...
Codesys Control For Beaglebone Sl
Codesys Control For Empc-a\\/imx6 Sl
Codesys Control For Iot2000 Sl
Codesys Control For Linux Sl
Codesys Control For Pfc100 Sl
Codesys Control For Pfc200 Sl
Codesys Raspberry Pi
Codesys Control Rte Sl
Codesys Control Win Sl
Codesys Development System
Codesys Runtime Toolkit
Codesys Hmi Sl
890
VMScore
CVE-2018-10612
In 3S-Smart Software Solutions GmbH CODESYS Control V3 products prior to version 3.5.14.0, user access management and communication encryption is not enabled by default, which could allow an attacker access to the device and sensitive information, including user credentials.
Codesys Control Win Sl
Codesys Development System V3
Codesys Hmi Sl
Codesys Control For Raspberry Pi Sl
Codesys Control Runtime Toolkit
Codesys Control For Empc-a\\/imx6 Sl
Codesys Control For Iot2000 Sl
Codesys Control For Linux Sl
Codesys Control For Pfc100 Sl
Codesys Control For Beaglebone Sl
Codesys Control For Pfc200 Sl
Codesys Control Rte Sl
571
VMScore
CVE-2022-22518
A bug in CmpUserMgr component can lead to only partially applied security policies. This can result in enabled, anonymous access to components part of the applied security policy.
Codesys Control For Beaglebone Sl
Codesys Control For Beckhoff Cx9020
Codesys Control For Empc-a\\/imx6 Sl
Codesys Control For Iot2000 Sl
Codesys Control For Linux Sl
Codesys Control For Pfc100 Sl
Codesys Control For Pfc200 Sl
Codesys Control For Raspberry Pi Sl
Codesys Control For Wago Touch Panels 600 Sl
Codesys Control Runtime System Toolkit
NA
CVE-2023-37545
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-se...
Codesys Control For Empc-a\\/imx6 Sl
Codesys Control For Beaglebone Sl
Codesys Control For Wago Touch Panels 600 Sl
Codesys Control For Raspberry Pi Sl
Codesys Control For Plcnext Sl
Codesys Control For Pfc200 Sl
Codesys Control For Pfc100 Sl
Codesys Control For Linux Sl
Codesys Control For Iot2000 Sl
Codesys Control Rte Sl \\(for Beckhoff Cx\\)
Codesys Safety Sil2
Codesys Hmi
Codesys Development System
Codesys Control Win Sl
Codesys Control Runtime System Toolkit
Codesys Control Rte Sl
NA
CVE-2023-37546
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-se...
Codesys Control For Empc-a\\/imx6 Sl
Codesys Control For Beaglebone Sl
Codesys Control For Wago Touch Panels 600 Sl
Codesys Control For Raspberry Pi Sl
Codesys Control For Plcnext Sl
Codesys Control For Pfc200 Sl
Codesys Control For Pfc100 Sl
Codesys Control For Linux Sl
Codesys Control For Iot2000 Sl
Codesys Control Rte Sl \\(for Beckhoff Cx\\)
Codesys Safety Sil2
Codesys Hmi
Codesys Development System
Codesys Control Win Sl
Codesys Control Runtime System Toolkit
Codesys Control Rte Sl
VMScore
CVSSv2
CVSSv3
VMScore
Recommendations:
SSTI
CVE-2024-35863
CVE-2024-35910
man-in-the-middle
CVE-2024-35912
CVE-2024-25742
LFI
CVE-2024-32002
CVE-2024-22120