Vulmon
Recent Vulnerabilities
Research Posts
Trends
Blog
About
Contact
Vulmon Alerts
By Relevance
By Risk Score
By Publish Date
deltaww vulnerabilities and exploits
(subscribe to this query)
7.8
CVSSv3
CVE-2018-14800
Delta Electronics ISPSoft version 3.0.5 and prior allow an attacker, by opening a crafted file, to cause the application to read past the boundary allocated to a stack object, which could allow execution of code under the context of the application.
Deltaww Ispsoft
6.1
CVSSv3
CVE-2021-23228
DIAEnergie Version 1.7.5 and prior is vulnerable to a reflected cross-site scripting attack through error pages that are returned by “.NET Request.QueryString”.
Deltaww Diaenergie
9.8
CVSSv3
CVE-2022-26013
Delta Electronics DIAEnergie (All versions before 1.8.02.004) has a blind SQL injection vulnerability that exists in DIAE_dmdsetHandler.ashx. This allows an malicious user to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands.
Deltaww Diaenergie
9.8
CVSSv3
CVE-2022-26065
Delta Electronics DIAEnergie (All versions before 1.8.02.004) has a blind SQL injection vulnerability exists in GetLatestDemandNode. This allows an malicious user to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands.
Deltaww Diaenergie
5.5
CVSSv3
CVE-2019-6547
Delta Industrial Automation CNCSoft, CNCSoft ScreenEditor Version 1.00.84 and prior. An out-of-bounds read vulnerability may cause the software to crash due to lacking user input validation for processing project files.
Deltaww Screeneditor
7.5
CVSSv3
CVE-2022-0988
Delta Electronics DIAEnergie (Version 1.7.5 and prior) is vulnerable to cleartext transmission as the web application runs by default on HTTP. This could allow an malicious user to remotely read transmitted information between the client and product.
Deltaww Diaenergie
7.8
CVSSv3
CVE-2022-1098
Delta Electronics DIAEnergie (all versions before 1.8.02.004) are vulnerable to a DLL hijacking condition. When combined with the Incorrect Default Permissions vulnerability of 4.2.2 above, this makes it possible for an malicious user to escalate privileges
Deltaww Diaenergie
9.8
CVSSv3
CVE-2021-38390
A Blind SQL injection vulnerability exists in the /DataHandler/HandlerEnergyType.ashx endpoint of Delta Electronics DIAEnergie Version 1.7.5 and prior. The application does not properly validate the user-controlled value supplied through the parameter egyid before using it as par...
Deltaww Diaenergie
4.8
CVSSv3
CVE-2021-38403
Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter supplier of the API maintenance, which may allow an malicious user to remotely execute code.
Deltaww Dialink
7.8
CVSSv3
CVE-2021-38406
Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when parsing specific project files. This could result in multiple out-of-bounds write instances. An attacker could leverage this vulnerability to execute code in the context of t...
Deltaww Dopsoft
CVSSv3
CVSSv2
CVSSv3
VMScore
Recommendations:
authentication bypass
CVE-2024-30051
remote
CVE-2024-27954
CVE-2023-51483
CVE-2023-47782
SSRF
CVE-2024-24715
CVE-2023-52424
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
« PREV
3
4
5
6
7
8
9
10
NEXT »