Vulmon
Recent Vulnerabilities
Research Posts
Trends
Blog
About
Contact
Vulmon Alerts
By Relevance
By Risk Score
By Publish Date
interactive graphical scada system vulnerabilities and exploits
(subscribe to this query)
9.8
CVSSv3
CVE-2022-24311
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inserting at beginning of file or create a new file in the context of the Data Server potentially leading to remote code execution when ...
Schneider-electric Interactive Graphical Scada System Data Server
9.8
CVSSv3
CVE-2022-24312
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by adding at end of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attack...
Schneider-electric Interactive Graphical Scada System Data Server
9.8
CVSSv3
CVE-2022-24313
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Ser...
Schneider-electric Interactive Graphical Scada System Data Server
7.5
CVSSv3
CVE-2022-24314
A CWE-125: Out-of-bounds Read vulnerability exists that could cause memory leaks potentially resulting in denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
Schneider-electric Interactive Graphical Scada System Data Server
7.5
CVSSv3
CVE-2022-24315
A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
Schneider-electric Interactive Graphical Scada System Data Server
7.5
CVSSv3
CVE-2022-24316
A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
Schneider-electric Interactive Graphical Scada System Data Server
7.5
CVSSv3
CVE-2022-24317
A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
Schneider-electric Interactive Graphical Scada System Data Server
NA
CVE-2011-1566
Directory traversal vulnerability in dc.exe 9.00.00.11059 and previous versions in 7-Technologies Interactive Graphical SCADA System (IGSS) allows remote malicious users to execute arbitrary programs via ..\ (dot dot backslash) sequences in opcodes (1) 0xa and (2) 0x17 to TCP por...
7t Igss
2 EDB exploits
NA
CVE-2011-4050
Buffer overflow in 7-Technologies (7T) Interactive Graphical SCADA System (IGSS) 9.0.0.11200 allows remote malicious users to cause a denial of service via a crafted packet to TCP port 12401.
7t Igss 9.0.0.11200
NA
CVE-2011-4053
Untrusted search path vulnerability in 7-Technologies (7T) Interactive Graphical SCADA System (IGSS) prior to 9.0.0.11291 allows local users to gain privileges via a Trojan horse DLL in the current working directory.
7t Igss 9.0.0.11129
7t Igss 8
7t Igss 6
7t Igss 2.0
7t Igss 5.1
7t Igss 5.0
7t Igss 4.1
7t Igss 3.0
7t Igss 9
7t Igss 7
7t Igss
CVSSv3
CVSSv2
CVSSv3
VMScore
Recommendations:
CVE-2020-4463
CVE-2024-29895
inject
CVE-2023-52689
CVE-2024-5049
CVE-2024-5051
privilege escalation
physical
CVE-2023-52676
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
« PREV
1
2
3
4
5
6
7
NEXT »