CVE-2020-16212
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource. The application on the surveillance station operates in kiosk mode, which is vuln...
Philips Patient Information Center Ix B.02
Philips Patient Information Center Ix C.02
Philips Patient Information Center Ix C.03
3.5
CVSSv3
CVE-2020-16218
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is then used as a webpage and served to other users. Successful exploitation could lead to un...
Philips Patient Information Center Ix B.02
Philips Patient Information Center Ix C.02
Philips Patient Information Center Ix C.03
5.5
CVSSv3
CVE-2021-43552
The use of a hard-coded cryptographic key significantly increases the possibility encrypted data may be recovered from the Patient Information Center iX (PIC iX) Versions B.02, C.02, and C.03.
Philips Patient Information Center Ix B.02
Philips Patient Information Center Ix C.02
Philips Patient Information Center Ix C.03
NA
CVE-2008-4874
The web component in Philips Electronics VOIP841 DECT Phone with firmware 1.0.4.50 and 1.0.4.80 has a back door "service" account with "service" as its password, which makes it easier for remote malicious users to obtain access.
Philips Electronics Voip841 Dect Phone 1.0.4.50
Philips Electronics Voip841 Dect Phone 1.0.4.48
1 EDB exploit
NA
CVE-2008-4875
Directory traversal vulnerability in the web server in Philips Electronics VOIP841 DECT Phone with firmware 1.0.4.50 and 1.0.4.80 allows remote authenticated users to read arbitrary files via a .. (dot dot) in a GET request. NOTE: this can be leveraged with CVE-2008-4874 for unau...
Philips Electronics Voip841 Dect Phone 1.0.4.50
Philips Electronics Voip841 Dect Phone 1.0.4.48
1 EDB exploit
NA
CVE-2008-4876
Cross-site scripting (XSS) vulnerability in the web server component in Philips Electronics VOIP841 DECT Phone with firmware 1.0.4.50 and 1.0.4.80 allows remote malicious users to inject arbitrary web script or HTML via the request URL, which is not properly handled in a 404 web ...
Philips Electronics Voip841 Dect Phone 1.0.4.50
Philips Electronics Voip841 Dect Phone 1.0.4.48
1 EDB exploit
6.5
CVSSv3
CVE-2017-9657
Under specific 802.11 network conditions, a partial re-association of the Philips IntelliVue MX40 Version B.06.18 WLAN monitor to the central monitoring station is possible. In this state, the central monitoring station can indicate the MX40 is not connected or associated to the ...
Philips Intellivue Mx40 Firmware
6.5
CVSSv3
CVE-2017-9658
Certain 802.11 network management messages have been determined to invoke wireless access point blacklisting security defenses when not required, which can necessitate intervention by hospital staff to reset the device and reestablish a network connection to the Wi-Fi access poin...
Philips Intellivue Mx40 Firmware
9.8
CVSSv3
CVE-2018-7498
In Philips Alice 6 System version R8.0.2 or prior, the lack of proper data encryption passes up the guarantees of confidentiality, integrity, and accountability that properly implemented encryption conveys.
Philips Alice 6 Firmware
7.5
CVSSv3
CVE-2018-7580
Philips Hue is vulnerable to a Denial of Service attack. Sending a SYN flood on port tcp/80 will freeze Philips Hue's hub and it will stop responding. The "hub" will stop operating and be frozen until the flood stops. During the flood, the user won't be able t...
Philips Hue Firmware
CVSSv3
CVSSv2
CVSSv3
VMScore
Recommendations:
CVE-2024-4946
CVE-2024-30309
CVE-2024-4761
CVE-2024-30051
type confusion
memory leak
CVE-2024-30293
reflected XSS
CVE-2024-3126
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
« PREV
1
2
3
4
5
6
7
8
9
10
NEXT »