5
CVSSv2
CVE-2018-8856
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software contains hard-coded cryptographic key, which it uses for encryption of internal data.
Philips E-alert Firmware
6.8
CVSSv2
CVE-2018-8852
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. When authenticating a user or otherwise establishing a new user session, the software gives an attacker the opportunity to steal authenticated sessions without invalidating any existing session identifier.
Philips E-alert Firmware
6.8
CVSSv2
CVE-2018-8844
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request.
Philips E-alert Firmware
5
CVSSv2
CVE-2018-8848
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software, upon installation, sets incorrect permissions for an object that exposes it to an unintended actor.
Philips E-alert Firmware
4.3
CVSSv2
CVE-2021-32966
Philips Interoperability Solution XDS versions 2.5 up to and including 3.11 and 2018-1 through 2021-1 are vulnerable to clear text transmission of sensitive information when configured to use LDAP via TLS and where the domain controller returns LDAP referrals, which may allow an ...
Philips Interoperability Solution Xds
2.1
CVSSv2
CVE-2019-10968
Philips Holter 2010 Plus, all versions. A vulnerability has been identified that may allow system options that were not purchased to be enabled.
Philips Zymed Holter 2010
3.3
CVSSv2
CVE-2018-8842
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. The Philips e-Alert communication channel is not encrypted which could...
Philips E-alert Firmware
3.3
CVSSv2
CVE-2020-16200
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The software does not properly control the allocation and maintenance of a limited resource, thereby enabling an malicious user to influence the amount of resources consumed, eventually leading to the exhaustion ...
Philips Clinical Collaboration Platform
3.5
CVSSv2
CVE-2015-2883
Philips In.Sight B120/37 has XSS, related to the Weaved cloud web service, as demonstrated by the name parameter to deviceSettings.php or shareDevice.php.
Philips In.sight B120\\\\37 -
6.5
CVSSv2
CVE-2021-39376
Philips Healthcare Tasy Electronic Medical Record (EMR) 3.06 allows SQL injection via the CorCad_F2/executaConsultaEspecifico IE_CORPO_ASSIST or CD_USUARIO_CONVENIO parameter.
Philips Tasy Electronic Medical Record 3.06
CVSSv2
CVSSv2
CVSSv3
VMScore
Recommendations:
CVE-2023-49333
CVE-2024-33901
CVE-2024-36001
CVE-2024-2835
firewall
XPath injection
authentication bypass
CVE-2024-22120
CVE-2024-32002
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
« PREV
5
6
7
8
9
10
NEXT »