A vulnerability has been identified in DIGSI 4 (All versions < V4.92), EN100 Ethernet module DNP3 variant (All versions < V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). The device engineering mechanism allows an unauthenticated remote user to upload a modified device configuration overwriting access authorization passwords.
Vulnerable Product | Search on Vulmon | Subscribe to Product |
---|---|---|
siemens siprotec_compact_7sj80_firmware |
||
siemens siprotec_compact_7sk80_firmware |
||
siemens siprotec_4_7sj66_firmware |
||
siemens digsi 4 |
||
siemens en100_ethernet_module_iec_104_firmware - |
||
siemens en100_ethernet_module_dnp3_firmware - |
||
siemens en100_ethernet_module_modbus_tcp_firmware - |
||
siemens en100_ethernet_module_profinet_io_firmware - |
||
siemens en100_ethernet_module_iec_61850_firmware |