A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “MKD/XMKD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0018)
Vulnerable Product | Search on Vulmon | Subscribe to Product |
---|---|---|
siemens nucleus source code |
||
siemens nucleus net |
||
siemens nucleus readystart v3 |
||
siemens apogee_modular_building_controller_firmware |
||
siemens apogee_modular_equiment_controller_firmware |
||
siemens apogee_pxc_compact_firmware |
||
siemens apogee_pxc_modular_firmware |
||
siemens talon_tc_compact_firmware |
||
siemens talon_tc_modular_firmware |
||
siemens desigo_pxc00-e.d_firmware |
||
siemens desigo_pxc00-u_firmware |
||
siemens desigo_pxc001-e.d_firmware |
||
siemens desigo_pxc12-e.d_firmware |
||
siemens desigo_pxc22-e.d_firmware |
||
siemens desigo_pxc22.1-e.d_firmware |
||
siemens desigo_pxc36.1-e.d_firmware |
||
siemens desigo_pxc50-e.d_firmware |
||
siemens desigo_pxc64-u_firmware |
||
siemens desigo_pxc100-e.d_firmware |
||
siemens desigo_pxc128-u_firmware |
||
siemens desigo_pxc200-e.d_firmware |
||
siemens desigo_pxm20-e_firmware |