7.5
CVSSv3

CVE-2022-30313

Published: 28/07/2022 Updated: 13/02/2024
CVSS v3 Base Score: 7.5 | Impact Score: 3.6 | Exploitability Score: 3.9
VMScore: 0

Vulnerability Summary

Honeywell Experion PKS Safety Manager through 2022-05-06 has Missing Authentication for a Critical Function. According to FSCT-2022-0051, there is a Honeywell Experion PKS Safety Manager multiple proprietary protocols with unauthenticated functionality issue. The affected components are characterized as: Honeywell Experion TCP (51000/TCP), Safety Builder (51010/TCP). The potential impact is: Manipulate controller state, Manipulate controller configuration, Manipulate controller logic, Manipulate controller files, Manipulate IO. The Honeywell Experion PKS Distributed Control System (DCS) Safety Manager utilizes several proprietary protocols for a wide variety of functionality, including process data acquisition, controller steering and configuration management. These protocols include: Experion TCP (51000/TCP) and Safety Builder (51010/TCP). None of these protocols have any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality. There is no authentication functionality on the protocols in question. An attacker capable of invoking the protocols' functionalities could achieve a wide range of adverse impacts, including (but not limited to), the following: for Experion TCP (51000/TCP): Issue IO manipulation commands, Issue file read/write commands; and for Safety Builder (51010/TCP): Issue controller start/stop commands, Issue logic download/upload commands, Issue file read commands, Issue system time change commands. A mitigating factor with regards to some, but not all, of the above functionality is that these require the Safety Manager physical keyswitch to be in the right position.

Vulnerability Trend

Vulnerable Product Search on Vulmon Subscribe to Product

honeywell safety_manager_firmware -

ICS Advisories

Recent Articles

CISA and friends raise alarm on critical flaws in industrial equipment, infrastructure
The Register • Jessica Lyons Hardcastle • 01 Jan 1970

Topics Security Off-Prem On-Prem Software Offbeat Vendor Voice Vendor Voice Resources Nearly 60 holes found affecting 'more than 30,000' machines worldwide

Fifty-six vulnerabilities – some deemed critical – have been found in industrial operational technology (OT) systems from ten global manufacturers including Honeywell, Ericsson, Motorola, and Siemens, putting more than 30,000 devices worldwide at risk, according to the US government's CISA and private security researchers.  Some of these vulnerabilities received CVSS severity scores as high as 9.8 out of 10. That is particularly bad, considering these devices are used in critical infras...